Arctic Sun Stat Temperature Management System
Arctic Sun Stat Temperature Management System Fill Tube
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1), Anhui (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sino Protection (Hefei) Medical Products Co., Ltd. | Hefei | Anhui | Contract manufacturer | 18 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Copious Intl., Inc. | Heyuan, Guangdong Province | Contract manufacturer | 11 | |
| Jiangyin Puremed | Jiangyin | Jiangsu | Contract manufacturer | 7 |
| Betacera Inc. | Suzhou | Jiangsu | Contract manufacturer | 3 |
| Shanghai Xodus Medical Company Limited | Shanghai | Shanghai | Specification developer | 25 |
| Hangzhou Tappa Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 3 |
| Jiangmen Dacheng Medical Equipment Co., Ltd. | Jiangmen | Guangdong | Contract manufacturer | 1 |
Record
| Listed by | Medivance, Inc., United States |
|---|---|
| FDA product code | DWJ |
| Device type | System, Thermal Regulating |
| Device class | Class 2 |
| Regulation | 21 CFR 870.5900 |
| Establishment | Specification developer, Manufacturer |
| Record published | 2024-08-26 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, manufacturing date |
| Storage | Storage environment temperature -30 to 50 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 72800 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Mistral-Air | The Surgical Company International B.V. | 114 |
| Bair Hugger™ | 3M Company | 99 |
| IOB | Jiangmen Dacheng Medical Equipment Co., Ltd. | 68 |
| IOB | Iob Medical, Inc. | 61 |
| 3M™ Bair Hugger™ | 3M Company | 61 |
| Cocoon | Care Essentials PTY Ltd | 59 |
| Soft Air | Adroit Medical Systems, Inc. | 56 |
| Level 1 | ICU Medical, Inc | 49 |
| System, Thermal Regulating | Hangzhou Tappa Medical Technology Co., Ltd. | 47 |
| PremierPro | Prestige Ameritech | 39 |
| Bair Paws™ | 3M Company | 30 |
| SourceMark | Sourcemark, LLC. | 25 |
Showing 12 of 166. All products under System, Thermal Regulating
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K251974 | 2025-10-24 |
| K243942 | 2025-04-30 |
| K200225 | 2020-02-28 |
| K161602 | 2016-09-02 |
| K142702 | 2014-12-18 |
| K120849 | 2012-07-20 |
| K101092 | 2010-07-16 |
| K071341 | 2007-08-03 |
| K010338 | 2001-03-07 |
| K002577 | 2000-10-26 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2024-06-27 | Class II | Software design | If temperature management system fails to reach correct target water temperature while device is operating in patient control mode, due to sudden patient temperature changes/interruption in water flow/blockage of air flow by an obstruction | 10507 | |
| 2024-02-16 | Class II | Process control | Neonatal pads are experiencing reduced water flow, which may reduce or prevent water heating or cooling performance of the pads that are part of a temperature management system. | 1,654 | |
| 2005-01-05 | Not classified | Other | Potential for an inaccuracy of the primary patient temperature reading that is used to monitor and control patient temperature. | 67 units | 2005-03-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.