Kool Kit® Neonate

Catalogue number 950, listed by Gentherm Medical, LLC, United States, under System, Thermal Regulating. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
1catalogue number
22recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1), Anhui (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DWJ
Manufacturer City Province Registered as Device types
Sino Protection (Hefei) Medical Products Co., Ltd. Hefei Anhui Contract manufacturer 18
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Copious Intl., Inc. Heyuan, Guangdong Province Contract manufacturer 11
Jiangyin Puremed Jiangyin Jiangsu Contract manufacturer 7
Betacera Inc. Suzhou Jiangsu Contract manufacturer 3
Shanghai Xodus Medical Company Limited Shanghai Shanghai Specification developer 25
Hangzhou Tappa Medical Technology Co., Ltd. Hangzhou Zhejiang Manufacturer 3
Jiangmen Dacheng Medical Equipment Co., Ltd. Jiangmen Guangdong Contract manufacturer 1

Record

Regulatory record for Kool Kit® Neonate
Listed by Gentherm Medical, LLC, United States
FDA product code DWJ
Device type System, Thermal Regulating
Device class Class 2
Regulation 21 CFR 870.5900
Establishment Specification developer, Manufacturer, Exporter
Record published 2017-08-30
Record revised 2023-12-18 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
Storage Storage environment temperature -40 to 150 °F; Storage environment temperature -40 to 65.6 °C; Storage environment humidity 20 to 95 % RH; Handling environment temperature 59 to 86 °F; Handling environment temperature 15 to 30 °C; Handling environment humidity 20 to 95 % RH
Sizes Depth 1.63 in; width 11 in; length 14.25 in; weight 0.15 lb

Catalogue Numbers

Catalogue numbers for Kool Kit® Neonate
Catalogue number Size Per pack Status
950 Depth 1.63 in 5 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Mistral-Air The Surgical Company International B.V. 114
Bair Hugger™ 3M Company 99
IOB Jiangmen Dacheng Medical Equipment Co., Ltd. 68
IOB Iob Medical, Inc. 61
3M™ Bair Hugger™ 3M Company 61
Cocoon Care Essentials PTY Ltd 59
Soft Air Adroit Medical Systems, Inc. 56
Level 1 ICU Medical, Inc 49
System, Thermal Regulating Hangzhou Tappa Medical Technology Co., Ltd. 47
PremierPro Prestige Ameritech 39
Bair Paws™ 3M Company 30
SourceMark Sourcemark, LLC. 25

Showing 12 of 166. All products under System, Thermal Regulating

Recalls

11 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-13 Class II Device Design Overheating occurring on 115V CPU boards for the Blanketrol III Model 233, Innercool CoolBlue Model STx, and Blanketrol II Model 222S products may cause the device to shut down. 182 units
2026-07-13 Class II Device Design Overheating occurring on 115V CPU boards for the Blanketrol III Model 233, Innercool CoolBlue Model STx, and Blanketrol II Model 222S products may cause the device to shut down. 46 units
2026-07-13 Class II Device Design Overheating occurring on 115V CPU boards for the Blanketrol III Model 233, Innercool CoolBlue Model STx, and Blanketrol II Model 222S products may cause the device to shut down, 9714 units
2019-07-02 Class II Labeling False and Misleading Warnings statements have been added- exceeding 40 degree C for extended periods may cause tissue damage. Additionally, a caution was added and clarifications were made regarding the use of the Automatic modes 3932 2020-06-22
2019-07-02 Class II Labeling False and Misleading Warnings statements have been added- exceeding 40 degree C for extended periods may cause tissue damage. Additionally, a caution was added and clarifications were made regarding the use of the Automatic modes 5291 2020-06-22
2019-07-02 Class II Labeling False and Misleading Warnings statements have been added- exceeding 40 degree C for extended periods may cause tissue damage. Additionally, a caution was added and clarifications were made regarding the use of the Automatic modes 3726 2020-06-22
2019-06-20 Class II Labeling False and Misleading The manual does not provide instruction stating that exceeding 40 Celsius for extended periods can cause tissue damage. 674 2020-06-09
2019-06-20 Class II Labeling False and Misleading The manual does not provide instruction stating that exceeding 40 Celsius for extended periods can cause tissue damage. 1063 2020-06-09
2014-01-08 Class II Mixed-up of materials/components The incorrect voltage component was placed into the device during manufacturing. This may make the device unable to maintain patient temperature during cooling mode. The device will continue to indicate that the unit is cooling because the 7 units 2014-06-06
2013-09-03 Class II Labeling Change Control During a label review it was discovered that both the Blanketrol III Operations (57201-N) & Operations & Technical (56201-Q) manuals had verbiage added back into the manual during ECN M111-4260 (released 12/29/2011) which was previously rem 115V – 396 units; 230V – 385 units 2014-08-22
2013-05-15 Class II Software Manufacturing/Software Deployment During a customer inquiry regarding a beta version of the Bill Data Export Software, Model USB-127, it was discovered that the wrong software version was released to a customer. 12 Units 2014-05-13
2012-02-03 Not classified Device Design Design error. The probe jack contacts (terminals on certain of the firm’s ECMO Heater devices are located too close to the solid state relay contacts (terminals) which can lead to the terminals coming into contact with one another. If this 298 units (115V=295 and 230V/240V=3) 2013-02-26
2011-10-27 Not classified Software design The suspect hyper-hypothermia device systems sold to physicians for research and/or the treatment of AIDS or Cancer patients, were not appropriately cleared by the FDA prior to distribution. 16 of these devices were distributed in the U.S., and two (2 2013-02-26
2011-10-27 Not classified Software design The suspect hyper-hypothermia device systems sold to physicians for research and/or the treatment of AIDS and Cancer patients, were not appropriately cleared by the FDA prior to distribution. A total of 20 devices were distributed in the U.S. & 3 units 2013-02-26
2011-07-20 Not classified Labeling design Cincinnati Sub-Zero is conducting a field correction due to changes that have been made to the WarmAir Model 135 devices Operation and Technical Manuals in order to comply with FDA device labeling regulations. 6561 units were distributed. 2013-07-05
2011-06-01 Not classified Device Design Due to its design the circuit breaker on the device could trip causing it to shut down and not provide heated air to the blanket. 5474 units 2013-08-02
2011-05-19 Not classified Nonconforming Material/Component A component defect. The recalling firm determined that one of the connectors attached to the firm’s WarmAir 134 device’s Printed Circuit Board (PCB) can overheat. Should this event occur, the excess heat build up within the device may res 463 units were distributed 2013-02-26
2011-05-02 Not classified Device Design The probe jack contacts (terminals) on certain of the firm’s ECMO Heater devices are located too close to the solid state relay contacts (terminals) which can lead to the terminals coming into contact with each other. If this situation occ 116 units 2013-03-07
2011-05-02 Not classified Device Design The probe jack contacts (terminals) on certain of the firm’s ECMO Heater devices are located too close to the solid state relay contacts (terminals) which can lead to the terminals coming into contact with each other. If this situation occ 212 units – U. S. distribution & 44 units foreign distributi 2013-03-07
2010-10-18 Not classified Other The firm initiated this recall due to changes that have been made to the Blanketrol III Model 233 device’s Operation and Operation/Technical Service Manuals, in order to stay in compliance with labeling regulations. 763 – 115V Blanketrol III Model 233; & 133 – 115V CoolBlue M 2013-03-08
2009-11-14 Not classified Other Product is labeled as “Sterile”. It was observed that incomplete seals were created in the packaging materials during production. When the seal is compromised, the sterility of the product inside the package cannot be assured. 1,095 Blankets 2012-01-25
2009-02-16 Not classified Process control The blower on the WarmAir 135 Warming Unit may overheat. Resistance in a connector between circuit board and wiring harness results in excessive heat that may melt connector or deform the outer casing of the blower unit. 2,674 units 2012-09-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer