Mul-T-Blanket
7 catalogue numbers from HP7010, listed by Stryker GmbH, Switzerland, under System, Thermal Regulating. 8 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1), Anhui (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sino Protection (Hefei) Medical Products Co., Ltd. | Hefei | Anhui | Contract manufacturer | 18 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Copious Intl., Inc. | Heyuan, Guangdong Province | Contract manufacturer | 11 | |
| Jiangyin Puremed | Jiangyin | Jiangsu | Contract manufacturer | 7 |
| Betacera Inc. | Suzhou | Jiangsu | Contract manufacturer | 3 |
| Shanghai Xodus Medical Company Limited | Shanghai | Shanghai | Specification developer | 25 |
| Hangzhou Tappa Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 3 |
| Jiangmen Dacheng Medical Equipment Co., Ltd. | Jiangmen | Guangdong | Contract manufacturer | 1 |
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | DWJ |
| Device type | System, Thermal Regulating |
| Device class | Class 2 |
| Regulation | 21 CFR 870.5900 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K100585 |
| Record published | 2016-09-24 |
| Record revised | 2023-12-18 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number |
| Storage | Handling environment temperature -40 to 140 °F; Handling environment humidity 10 to 95 % RH; Storage environment humidity 10 to 95 % RH; Storage environment temperature -40 to 140 °F |
| Packaging | Case of 10 |
| Distribution end date | 2025-06-20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| HP7010 | In distribution | |
| 8001-061-702 | Withdrawn | |
| 8001-061-612 | Withdrawn | |
| 8001-061-701 | Withdrawn | |
| 8001-061-610 | Withdrawn | |
| 8001-061-810 | Withdrawn | |
| 8001-061-812 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Mistral-Air | The Surgical Company International B.V. | 114 |
| Bair Hugger™ | 3M Company | 99 |
| IOB | Jiangmen Dacheng Medical Equipment Co., Ltd. | 68 |
| IOB | Iob Medical, Inc. | 61 |
| 3M™ Bair Hugger™ | 3M Company | 61 |
| Cocoon | Care Essentials PTY Ltd | 59 |
| Soft Air | Adroit Medical Systems, Inc. | 56 |
| Level 1 | ICU Medical, Inc | 49 |
| System, Thermal Regulating | Hangzhou Tappa Medical Technology Co., Ltd. | 47 |
| PremierPro | Prestige Ameritech | 39 |
| Bair Paws™ | 3M Company | 30 |
| SourceMark | Sourcemark, LLC. | 25 |
Showing 12 of 166. All products under System, Thermal Regulating
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K180834 | 2018-08-10 |
| K171149 | 2017-07-18 |
| K152266 | 2016-12-02 |
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-09-06 | Class II | Software design | Users may experience alarm fatigue due to frequent alarming relating to patient temperature deviation beyond 0.5C while in Automatic mode. 2. Users may experience a Remove from Use code 9 (RFU 9) fault condition relating to inadvertent flow | 389 units | 2020-04-13 |
| 2017-07-21 | Class II | Component design/selection | It was identified that the Mistral-Air Premium blankets may be capable of conducting electricity during a defibrillation or cardioversion therapy at higher energy levels (70 Joules or more) when the blanket is applied with the reflective si | 11160 | 2018-03-22 |
| 2017-03-29 | Class II | Software design | The water may reheat too quickly if the unit is in “Automatic” mode, switched to “Manual” mode to view water temperature, and then switched back to “Automatic” mode. | 119 | 2017-09-18 |
| 2013-12-27 | Class II | Device Design | Stryker Medical has identified that on some units of the MTA7900, there is a lack of a water temperature display while the unit is in Auto mode. While in Auto mode, only the patient temperature is displayed along with the set point. The wa | 1002 units | 2014-11-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.