Mul-T-Blanket

7 catalogue numbers from HP7010, listed by Stryker GmbH, Switzerland, under System, Thermal Regulating. 8 manufacturers in China are registered for this product code.

Registry build 21.09.26
8manufacturers in China registered for this device type
7catalogue numbers in this listing
3510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Shanghai (1), Anhui (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code DWJ
Manufacturer City Province Registered as Device types
Sino Protection (Hefei) Medical Products Co., Ltd. Hefei Anhui Contract manufacturer 18
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Copious Intl., Inc. Heyuan, Guangdong Province Contract manufacturer 11
Jiangyin Puremed Jiangyin Jiangsu Contract manufacturer 7
Betacera Inc. Suzhou Jiangsu Contract manufacturer 3
Shanghai Xodus Medical Company Limited Shanghai Shanghai Specification developer 25
Hangzhou Tappa Medical Technology Co., Ltd. Hangzhou Zhejiang Manufacturer 3
Jiangmen Dacheng Medical Equipment Co., Ltd. Jiangmen Guangdong Contract manufacturer 1

Record

Regulatory record for Mul-T-Blanket
Listed by Stryker GmbH, Switzerland
FDA product code DWJ
Device type System, Thermal Regulating
Device class Class 2
Regulation 21 CFR 870.5900
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
510(k) K100585
Record published 2016-09-24
Record revised 2023-12-18 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number
Storage Handling environment temperature -40 to 140 °F; Handling environment humidity 10 to 95 % RH; Storage environment humidity 10 to 95 % RH; Storage environment temperature -40 to 140 °F
Packaging Case of 10
Distribution end date 2025-06-20

Catalogue Numbers

Catalogue numbers for Mul-T-Blanket
Catalogue number Size Status
HP7010 In distribution
8001-061-702 Withdrawn
8001-061-612 Withdrawn
8001-061-701 Withdrawn
8001-061-610 Withdrawn
8001-061-810 Withdrawn
8001-061-812 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Mistral-Air The Surgical Company International B.V. 114
Bair Hugger™ 3M Company 99
IOB Jiangmen Dacheng Medical Equipment Co., Ltd. 68
IOB Iob Medical, Inc. 61
3M™ Bair Hugger™ 3M Company 61
Cocoon Care Essentials PTY Ltd 59
Soft Air Adroit Medical Systems, Inc. 56
Level 1 ICU Medical, Inc 49
System, Thermal Regulating Hangzhou Tappa Medical Technology Co., Ltd. 47
PremierPro Prestige Ameritech 39
Bair Paws™ 3M Company 30
SourceMark Sourcemark, LLC. 25

Showing 12 of 166. All products under System, Thermal Regulating

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K180834 2018-08-10
K171149 2017-07-18
K152266 2016-12-02

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-09-06 Class II Software design Users may experience alarm fatigue due to frequent alarming relating to patient temperature deviation beyond 0.5C while in Automatic mode. 2. Users may experience a Remove from Use code 9 (RFU 9) fault condition relating to inadvertent flow 389 units 2020-04-13
2017-07-21 Class II Component design/selection It was identified that the Mistral-Air Premium blankets may be capable of
conducting electricity during a defibrillation or cardioversion therapy at higher
energy levels (70 Joules or more) when the blanket is applied with the reflective
si
11160 2018-03-22
2017-03-29 Class II Software design The water may reheat too quickly if the unit is in “Automatic” mode, switched to “Manual” mode to view water temperature,
and then switched back to “Automatic” mode.
119 2017-09-18
2013-12-27 Class II Device Design Stryker Medical has identified that on some units of the MTA7900, there is a lack of a water temperature display while the unit is in Auto mode. While in Auto mode, only the patient temperature is displayed along with the set point. The wa 1002 units 2014-11-04

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer