System, Thermal Regulating
Connector 1393 Hansen Quick 90' Angle
8manufacturers in China registered for this device type
2catalogue numbers in this listing
Who Else Makes It
Concentrated in Jiangsu (3), Shanghai (1), Anhui (1). 5 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sino Protection (Hefei) Medical Products Co., Ltd. | Hefei | Anhui | Contract manufacturer | 18 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Copious Intl., Inc. | Heyuan, Guangdong Province | Contract manufacturer | 11 | |
| Jiangyin Puremed | Jiangyin | Jiangsu | Contract manufacturer | 7 |
| Betacera Inc. | Suzhou | Jiangsu | Contract manufacturer | 3 |
| Shanghai Xodus Medical Company Limited | Shanghai | Shanghai | Specification developer | 25 |
| Hangzhou Tappa Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 3 |
| Jiangmen Dacheng Medical Equipment Co., Ltd. | Jiangmen | Guangdong | Contract manufacturer | 1 |
Record
| Listed by | Medtronic, Inc., United States |
|---|---|
| FDA product code | DWJ |
| Device type | System, Thermal Regulating |
| Device class | Class 2 |
| Regulation | 21 CFR 870.5900 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K894980 |
| Record published | 2016-05-02 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1392 | In distribution | |
| 1393 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Mistral-Air | The Surgical Company International B.V. | 114 |
| Bair Hugger™ | 3M Company | 99 |
| IOB | Jiangmen Dacheng Medical Equipment Co., Ltd. | 68 |
| IOB | Iob Medical, Inc. | 61 |
| 3M™ Bair Hugger™ | 3M Company | 61 |
| Cocoon | Care Essentials PTY Ltd | 59 |
| Soft Air | Adroit Medical Systems, Inc. | 56 |
| Level 1 | ICU Medical, Inc | 49 |
| System, Thermal Regulating | Hangzhou Tappa Medical Technology Co., Ltd. | 47 |
| PremierPro | Prestige Ameritech | 39 |
| Bair Paws™ | 3M Company | 30 |
| SourceMark | Sourcemark, LLC. | 25 |
Showing 12 of 166. All products under System, Thermal Regulating
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Medtronic Perfusion Systems | 510(k) number | 2018-02-08 | Class II | Device Design | Medtronic has been unable to develop a cleaning protocol to satisfy current industry concerns and expectations. As a result, an updated cleaning protocol will not be developed by Medtronic and it has been determined that the best course of | 1980 units | 2020-08-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.