Multi-Snare®
Multi-Snare Micrset 2MMX175CM W3FRX150CM
1manufacturer
7catalogue numbers in this listing
Who Else Makes It
Registered in Shandong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
Record
| Listed by | B. Braun Interventional Systems, Inc., United States |
|---|---|
| FDA product code | DXE |
| Device type | Catheter, Embolectomy |
| Device class | Class 2 |
| Regulation | 21 CFR 870.5150 |
| 510(k) | K011783 |
| Record published | 2016-08-09 |
| Record revised | 2022-11-02 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: KEEP DRY; Special storage condition: ROOM TEMP AWAY FROM SUNLIGHT |
| Distribution end date | 2021-07-09 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 612970 | Withdrawn | |
| 612975 | Withdrawn | |
| 612976 | Withdrawn | |
| 612974 | Withdrawn | |
| 612972 | Withdrawn | |
| 612971 | Withdrawn | |
| 612973 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| LeMaitre Embolectomy Catheter | Lemaitre Vascular, Inc. | 68 |
| LMI Arterial Embolectomy Catheter | Lucas Medical, Inc. | 63 |
| Indigo System | Penumbra Inc. | 60 |
| Fogarty | Edwards Lifesciences Technology Sarl | 44 |
| Arrow | Teleflex Medical LLC | 28 |
| Bard Latex-free Arterial Embolectomy Catheters | Applied Medical Resources Corp. | 22 |
| Biosensors Embolectomy Catheter | Bioptimal International Pte. Ltd. | 16 |
| Amplatz Goose Neck | Covidien LP | 15 |
| Amplatz Goose Neck™ | ev3, Inc. | 13 |
| LMI Thrombectomy Catheter | Lucas Medical, Inc. | 12 |
| LMI Occlusion Catheter | Lucas Medical, Inc. | 12 |
| Syntel Thrombectomy Catheter | Applied Medical Resources Corp. | 9 |
Showing 12 of 88. All products under Catheter, Embolectomy
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| PFM Medical, Inc | 510(k) number | 2026-04-21 | Class II | Under Investigation by firm | A snare catheter including luer lock, indicated for removal or manipulation of a foreign body in the vascular system, failed to meet the biocompatibility requirements for in-vitro-cytotoxicity, which if in contact with a patient’s vasculatu | 32 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.