Octane™
2 catalogue numbers from 5071, listed by Vascular Solutions LLC, United States, under Catheter, Embolectomy. 1 manufacturer in China is registered for this product code.
Who Else Makes It
Registered in Shandong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Bioxin Medical Co., Ltd. | Weihai | Shandong | Contract manufacturer | 8 |
Record
| Listed by | Vascular Solutions LLC, United States |
|---|---|
| FDA product code | DXE |
| Device type | Catheter, Embolectomy |
| Device class | Class 2 |
| Regulation | 21 CFR 870.5150 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer |
| Record published | 2018-01-08 |
| Record revised | 2023-06-06 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Sizes | Total volume 500 ml; catheter gauge 8 Fr |
| Distribution end date | 2020-11-12 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5071 | Total Volume 500 ml | Withdrawn |
| 5072 | Catheter Gauge 8 Fr | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| LeMaitre Embolectomy Catheter | Lemaitre Vascular, Inc. | 68 |
| LMI Arterial Embolectomy Catheter | Lucas Medical, Inc. | 63 |
| Indigo System | Penumbra Inc. | 60 |
| Fogarty | Edwards Lifesciences Technology Sarl | 44 |
| Arrow | Teleflex Medical LLC | 28 |
| Bard Latex-free Arterial Embolectomy Catheters | Applied Medical Resources Corp. | 22 |
| Biosensors Embolectomy Catheter | Bioptimal International Pte. Ltd. | 16 |
| Amplatz Goose Neck | Covidien LP | 15 |
| Amplatz Goose Neck™ | ev3, Inc. | 13 |
| LMI Thrombectomy Catheter | Lucas Medical, Inc. | 12 |
| LMI Occlusion Catheter | Lucas Medical, Inc. | 12 |
| Syntel Thrombectomy Catheter | Applied Medical Resources Corp. | 9 |
Showing 12 of 88. All products under Catheter, Embolectomy
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2011-07-11 | Not classified | Process control | Vascular Solutions , Inc recently discovered that there was a manufacturing defect with Pronto V4 extraction catheters (Models 4005, 4006, 4007, 4008). Use of this defective product could lead to a tip separation. This may cause injury and/ | 1086 | 2012-04-03 |
| 2009-11-20 | Not classified | Process control | It was found that three Pronto Short (model 5030) device lots were manufactured and labeled with an expiration date which is inconsistent than the expiration of the included guidewire component. The guidewire is sterilized separately and w | 274 (150 US, 124 OUS) | 2012-04-05 |
| 2004-05-12 | Not classified | Other | The marker band in guidewire lumen could move from the manufactured location during clinical use. | 1010 of all affected lots | 2005-11-03 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.