R2
R2 Multifunction Electrode Accessories, Hewlett Packard Codemaster TO R2 Multifunction Adapter
Who Else Makes It
All of them in Guangdong. 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Amphenol Alden Products Company | Shenzhen | Guangdong | Contract manufacturer | 24 |
| EMI (Dongguan) Asia Limited | Dongguan | Guangdong | Contract manufacturer | 9 |
Record
| Listed by | ConMed Corporation, United States |
|---|---|
| FDA product code | LDD |
| Device type | Dc-Defibrillator, Low-Energy, (Including Paddles) |
| Device class | Class 2 |
| Regulation | 21 CFR 870.5300 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2015-10-24 |
| Record revised | 2025-08-18 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Handling environment humidity up to 85 % RH; Storage environment temperature 41 to 95 °F; Storage environment humidity 10 to 90 % RH; Handling environment temperature -4 to 131 °F; Storage environment temperature 5 to 35 °C; Handling environment temperature -20 to 55 °C |
| Distribution end date | 2020-10-21 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 32-184572X | In distribution | |
| 3200-1715 | Withdrawn | |
| 32-170471 | Withdrawn | |
| 32-184554 | Withdrawn | |
| 32-184571X | Withdrawn | |
| 3114-1741 | Withdrawn | |
| 32-170555 | Withdrawn | |
| 3111-1720 | Less than or equal to 100J/25kg | Withdrawn |
| 32-184554X | Withdrawn | |
| 32-170470 | Withdrawn | |
| 3111-1721 | Withdrawn | |
| 3115-1751 | Withdrawn | |
| 32-184572 | Withdrawn | |
| 3114-1740 | Withdrawn | |
| 3200-1711 | Withdrawn | |
| 32-184571 | Withdrawn | |
| 3115-1750 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Unipower | Unipower Corp. | 623 |
| Internal Handle | Zoll Medical Corporation | 89 |
| Vermed | Nissha Medical Technologies Limited | 47 |
| Cardio Clear | Cardio Medical Products, Inc. | 33 |
| Dc-Defibrillator, Low-Energy, (Including Paddles) | Fiab SPA | 20 |
| Dc-Defibrillator, Low-Energy, (Including Paddles) | Physio-Control, Inc. | 20 |
| HeartStart | Philips Medical Systems Hsg | 9 |
| Anybattery | Anybattery, Inc | 6 |
| Tempus LS-Manual | Remote Diagnostic Technologies Ltd. | 6 |
| Vermed Defib Pads | Graphic Controls Acquisition Corporation | 5 |
| HeartStart | Philips Electronics North America Corporation | 4 |
| Heartsync by Vermed | Graphic Controls Acquisition Corporation | 4 |
Showing 12 of 29. All products under Dc-Defibrillator, Low-Energy, (Including Paddles)
Recalls
2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2014-11-06 | Class I | Device Design | Philips Healthcare made changes to the design of the connection between multifunction electrodes and their HeartStart FR3 and HeartStart FRx AEDs. The failure to connect may result in a delay of therapy, which could result in patient death | 174,610 (168,090 US and 6,520 OUS) in total. | 2017-10-30 |
| 2014-11-06 | Class I | Device Design | Philips Healthcare made changes to the design of the connection between multifunction electrodes and their HeartStart FR3 and HeartStart FRx AEDs. The failure to connect may result in a delay of therapy, which could result in patient death | 174,610 (168,090 US and 6,520 OUS) in total. | 2017-10-30 |
| 2011-03-09 | Not classified | Packaging process control | The product lot was assembled with an R2 Connector, rather than a Zoll Connector. | 190 sets (2 pads per set in individual pouch) | 2012-01-12 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.