Chocolate Ptca BAlloon Catheter
Chocolate PTCA Balloon Catheter is a rapid-exchange catheter for dilating narrowed coronary arteries or bypass grafts. A metal constraining structure surrounds the semicompliant balloon at…
Chocolate PTCA Balloon Catheter is a rapid-exchange catheter for dilating narrowed coronary arteries or bypass grafts. A metal constraining structure surrounds the semicompliant balloon at the catheter’s distal end.
During inflation, the constraining structure expands with the balloon to a defined diameter, after which the balloon expands beyond it. During deflation, the structure returns toward its original shape and is removed with the catheter.
Catheter Construction
The shaft combines a stainless steel hypotube and nylon section with an atraumatic distal tip. Two radiopaque markers define the balloon’s working length. The catheter is approximately 140 cm long, accepts a 0.014-inch guidewire and connects through a proximal hub to a standard inflation device.
Who Else Makes It
Concentrated in Jiangsu (4), Guangdong (3), Beijing (2).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
| Goals Sterilization Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 26 |
| Wuxi Goals Medical Technology Co., Ltd. | Yixing | Jiangsu | Contract manufacturer | 24 |
| Suzhou Prosteri Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 20 |
| Lepu Medical Technology (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Beijing Target Medical Technologies Inc. | Beijing | Beijing | Contract manufacturer | 7 |
| OrbusNeich Medical (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Complaint-file establishment | 5 |
| Brosmed Medical Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 4 |
| Dongguan TT Medical, Inc. | Dongguan | Guangdong | Manufacturer | 4 |
| Kossel Medtech (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 4 |
| Shanghai Microport Medical (Group) Co., Ltd. | Shanghai | Shanghai | Specification developer | 1 |
| Sino Medical Sciences Technology Inc. | Tianjin | Tianjin | Manufacturer | 1 |
Record
| Listed by | Trireme Medical, Inc., United States |
|---|---|
| FDA product code | LOX |
| Device type | Catheters, Transluminal Coronary Angioplasty, Percutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 870.5100 |
| 510(k) | K133633 |
| Record published | 2017-02-13 |
| Record revised | 2019-10-07 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution | |
| A | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| NC Emerge® | Boston Scientific Corporation | 144 |
| Sprinter® Legend | Medtronic, Inc. | 133 |
| NC Quantum Apex™ | Boston Scientific Corporation | 128 |
| Trek | Abbott Vascular | 120 |
| Emerge™ | Boston Scientific Corporation | 119 |
| NC Trek | Abbott Vascular | 118 |
| Apex™ | Boston Scientific Corporation | 116 |
| Maverick²™ | Boston Scientific Corporation | 113 |
| Apollo Balloon Dilatation Catheter | Brosmed Medical Co., Ltd. | 110 |
| Sprinter® | Medtronic, Inc. | 108 |
| NC Stormer™ OTW | Medtronic, Inc. | 108 |
| Quantum™ Maverick™ | Boston Scientific Corporation | 106 |
Showing 12 of 67. All products under Catheters, Transluminal Coronary Angioplasty, Percutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K153682 | 2016-06-23 |
| K150292 | 2015-04-09 |
| K133633 | 2014-06-02 |
| K121681 | 2012-06-26 |
| K111544 | 2012-03-02 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P020037 | 2003-06-11 | FX MINIRAIL RX PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA) CATHETER | Abbott Vascular |
| P790017 | 2003-03-04 | NC STORMER OVER-THE-WIRE BALLOON DILATATION CATHETER AND NC STORMER ZIPPER MX BALLOON DILATATION CATHETER | Medtronic Ireland |
| P880027 | 2002-06-25 | PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY (PTCA) | Boston Scientific Corporation |
| P860019 | 2000-12-08 | MAXXUM AND NC MAXXUM PTCA CATHETER | Scimed Life Systems, Inc. |
| P880003 | 2000-07-07 | NINJA FX PTCA DILATATION CATHETER | Cordis Corp. |
| P990008 | 1999-09-27 | COOK MBC PTCA BALLOON DILATATION CATHETER | Cook Incorporated |
| P960014 | 1998-10-05 | MAGELLAN-C PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY(PTCA) CATHETERS MODEL C22020,C22520,C23020,& C23520 | Global Therapeutics, Inc. |
| P970052 | 1998-04-08 | LYNX CONTOUR CORONARY BALLOON DILATATION CATHETER(A NEW MODEL OF THE FACT CATHETER). | Endologix LLC |
| P930012 | 1997-05-29 | THE WRAP(PTCA) CATHETER | Progressive Angioplasty Systems, Inc. |
| P910031 | 1996-12-02 | FACT(TM)AND ARC BALLOON CORNARY DILATATION CATHETERS | Abbott Vascular Devices |
| P890048 | 1996-11-26 | USCI(R) PROBE III(TM) BALLOON-ON-A-WIRE(TM) D. SYS | Usci, Div. C.R. Bard, Inc. |
| P890001 | 1996-06-07 | LEOCOR PICO RUNNER(TM) PTCA CATHETER | Leocor, Inc. |
| P850021 | 1995-07-12 | HYBRID (PTCA) CATHETER | Abbott Vascular |
| P940009 | 1994-09-29 | PERCUTANEUS TRANSLUMINAL CORONARY ANGIOPLASTY CATH | Scimed Life Systems, Inc. |
| P890032 | 1992-07-23 | CORDIS ORION STEERABLE PTCA BALLOON CATHETER | Cordis Corp. |
| P880055 | 1991-07-19 | MICROSS-SL(TM) PTCA DILATATION CATHETER | Boston Scientific Corporation |
| P840040 | 1991-01-30 | HEART TRAK PTCA CATHETER | Boston Scientific Corporation |
| P810046 | 1990-10-05 | ACS RX(R) –.014 CORONARY DILATATION CATHETER | Advanced Cardiovascular Systems, Inc. |
| P870021 | 1990-10-04 | PRIME{TM} MODEL 6520, 6525, 6530 AND 6535 | Medtronic, Inc. |
| P880065 | 1990-09-19 | MANSFIELD SCI. AORTIC VALVULOPLASTY CATHETER | Boston Scientific Corporation |
| P870036 | 1989-06-23 | VERSAFLEX BUCHBINDER OMNIFLEX PTCA CATHETER SYSTEM | Medtronics Interventional Vascular |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.