Triglycerides (Trigs)

For the quantitative in vitro determination of Triglycerides in serum.

Registry build 21.09.26
2manufacturers in China registered for this device type
4catalogue numbers in this listing
2510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Shandong (1), Zhejiang (1).

Chinese manufacturers registered for FDA product code CDT
Manufacturer City Province Registered as Device types
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Hangzhou Lysun Biotechnology Co., Ltd. Hangzhou Zhejiang Manufacturer 22

Record

Regulatory record for Triglycerides (Trigs)
Listed by Randox Laboratories Limited, United Kingdom
FDA product code CDT
Device type Lipase Hydrolysis/Glycerol Kinase Enzyme, Triglycerides
Device class Class 1
Regulation 21 CFR 862.1705
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer
Premarket notification Exempt
Record published 2019-06-03
Record revised 2023-07-06 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for Triglycerides (Trigs)
Catalogue number Size Status
TR8147 In distribution
TR9780 In distribution
TR8332 In distribution
TR8067 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Biobase Biobase Biodustry(Shandong)Co., Ltd. 20
JAS Diagnostics Drew Scientific, Ltd. 8
Pointe Scientific, Inc. Horiba Instruments Incorporated 7
Synermed® Infrared Laboratory Systems LLC 6
AU Beckman Coulter, Inc. 5
Triglycerides Roche Diagnostics Gmbh 4
Carolina Liquid Chemistries Corp.® Triglycerides Reagent KIT DT213 Carolina Liquid Chemistries 4
Vitros Ortho-Clinical Diagnostics, Inc. 3
Teco Diagnostics Triglyceride – GPO Liquid Reagent Set Teco Diagnostics 3
Triglycerides/Glycerol Blanked Roche Diagnostics Gmbh 2
Triglyceride-SL Sekisui Diagnostics, LLC 2
Teco Diagnostics Triglyceride -GPO Reagent Set Teco Diagnostics 2

Showing 12 of 48. All products under Lipase Hydrolysis/Glycerol Kinase Enzyme, Triglycerides

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K150819 2015-08-06
K923508 1993-07-28

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-03-02 Class II Under Investigation by firm Randox has now released further steps to avoid contamination of the Lipase Assay on Rx instruments. 8 2019-04-11
2016-08-02 Class II Nonconforming Material/Component According to the firm carry over was observed when the Lipase test is run directly before or after the LDL and Triglycerides assays. Customers are instructed to amend the running order for all instruments using these reagents to ensure Lipa 18 2017-09-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer