Architect

ICT Urine Calibrator

Registry build 21.09.26
2manufacturers in China registered for this device type
3catalogue numbers in this listing
4510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

All of them in Guangdong.

Chinese manufacturers registered for FDA product code CEM
Manufacturer City Province Registered as Device types
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56

Record

Regulatory record for Architect
Listed by Abbott Laboratories, United States
FDA product code CEM
Device type Electrode, Ion Specific, Potassium
Device class Class 2
Regulation 21 CFR 862.1600
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2016-06-06
Record revised 2023-09-20 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 15 to 30 °C
Distribution end date 2021-03-26

Catalogue Numbers

Catalogue numbers for Architect
Catalogue number Size Status
2P32-11 In distribution
1J72-20 In distribution
1E47-02 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Nova Nova Biomedical Corporation 8
Stat Profile Nova Biomedical Corporation 7
Potassium electrode Roche Diagnostics Gmbh 4
Potassium Electrode Diamond Diagnostics Inc. 3
Synermed® Infrared Laboratory Systems LLC 3
Phoenix Diagnostics, Inc. Phoenix Diagnostics, Inc. 2
I.S.E. K Randox Laboratories Limited 2
Pointe Scientific, Inc. Horiba Instruments Incorporated 2
Potassium Electrode Medica Corp. 2
Na/K Solution Pack Medica Corp. 2
Selectra VitalScientific B.V. 2
FlexLab Inpeco SA 1

Showing 12 of 93. All products under Electrode, Ion Specific, Potassium

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K093318 2010-02-19
K993083 1999-10-05
K884566 1988-12-02
K850950 1985-08-12

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-04-02 Class II Software Design Change In the case of an AQM clot detection error a portion of the distilled water from the Aliquoter Module hydraulic circuit may be dispensed into the Primary Tube leading to sample dilution, which could lead to incorrect results. 11 2021-04-28
2014-07-22 Class II Process control ICT Serum Calibrator may generate lower than expected Potassium Quality Control (QC) and patient results on the Abbott Architect cSystem. 11,215 units 2015-07-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer