Atellica IM IRI
Insulin (IRI) - Atellica IM - RGT 100T
4manufacturers in China registered for this device type
2catalogue numbers in this listing
3recalls on this code
Who Else Makes It
Concentrated in Jilin (1), Guangdong (1), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Shenzhen Yhlo Biotech Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 19 |
| Getein Biotech, Inc. | Nanjing | Jiangsu | Manufacturer | 19 |
| Beijing Hotgen Biotech Co., Ltd. | Beijing | Beijing | Manufacturer | 13 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | CFP |
| Device type | Radioimmunoassay, Immunoreactive Insulin |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1405 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2020-09-24 |
| Record revised | 2021-11-18 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Store Upright, Protect from Light, Do not freeze, Resuspend.; Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10995628 | In distribution | |
| 11206267 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Salimetrics | Salimetrics LLC. | 2 |
| Elecsys Insulin | Roche Diagnostics Gmbh | 2 |
| Insulin | DRG Instruments Gesellschaft mit beschränkter Haftung | 2 |
| Insulin Elisa | DRG Instruments Gesellschaft mit beschränkter Haftung | 2 |
| Immulite® 2000 Systems INS Insulin | Siemens Healthcare Diagnostics Products GmbH | 2 |
| Atellica IM IRI DIL | Siemens Healthcare Diagnostics Inc | 2 |
| Advia Centaur® IRI | Siemens Healthcare Diagnostics Inc | 2 |
| Anti-Insulin Elisa | DRG Instruments Gesellschaft mit beschränkter Haftung | 2 |
| Architect | Abbott Medical | 1 |
| Insulin Elisa Kit (Dako) | Mercodia AB | 1 |
| Insulin AccuBind Elisa Test System – 96 Wells | Monobind, Inc. | 1 |
| Mercodia Ultrasensitive Insulin Elisa | Mercodia AB | 1 |
Showing 12 of 48. All products under Radioimmunoassay, Immunoreactive Insulin
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Closed |
|---|---|---|---|---|
| 2017-04-05 | Class II | Nonconforming Material/Component | Current lots of ADVIA Centaur/XP/XPT/CP Insulin (IRI) assay recover approximately 40% higher than the World Health Organization (WHO) 1st IRP 66/304 standardization based on slope values. Other performance characteristics are being met per | 2019-04-02 |
| 2012-04-30 | Not classified | Component change control | Siemens Healthcare Diagnostics has observed a negative bias in the Immulite Insulin assay. | 2017-03-16 |
| 2012-04-30 | Not classified | Component change control | Siemens Healthcare Diagnostics has observed a negative bias in the Immulite Insulin assay. | 2017-03-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.