Vitros

VITROS Immunodiagnostic Products Prolactin Reagent Pack

Registry build 21.09.26
6manufacturers in China registered for this device type
2catalogue numbers in this listing
2recalls on this code

Who Else Makes It

Concentrated in Jilin (1), Shandong (1), Hebei (1).

Chinese manufacturers registered for FDA product code CFT
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Shijiazhuang Hipro Biotechnology Co., Ltd. Shijiazhuang Hebei Manufacturer 22
Shenzhen Yhlo Biotech Co., Ltd. Shenzhen Guangdong Manufacturer 19
Getein Biotech, Inc. Nanjing Jiangsu Manufacturer 19
Beijing Hotgen Biotech Co., Ltd. Beijing Beijing Manufacturer 13

Record

Regulatory record for Vitros
Listed by Ortho-Clinical Diagnostics, Inc., United States
FDA product code CFT
Device type Radioimmunoassay, Prolactin (Lactogen)
Device class Class 1
Regulation 21 CFR 862.1625
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2022-10-24
Record revised 2025-02-19 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date
Storage Storage environment temperature 2 to 8 °C; Special storage condition: Do not freeze
Packaging Case of 30

Catalogue Numbers

Catalogue numbers for Vitros
Catalogue number Size Status
6199337 In distribution
1849793 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Elecsys Prolactin II Roche Diagnostics Gmbh 3
Atellica IM PRL Siemens Healthcare Diagnostics Inc 3
Advia Centaur® PRL Siemens Healthcare Diagnostics Inc 2
Architect Abbott Ireland 2
Prolactin Elisa DRG International, Inc. 2
Alinity Abbott Ireland 2
Immulite® 2000 Systems PRL Prolactin Siemens Healthcare Diagnostics Products GmbH 2
Prolactin DRG Instruments Gesellschaft mit beschränkter Haftung 2
Prolactin Elisa DRG Instruments Gesellschaft mit beschränkter Haftung 2
Monobind AccuBind PRL Elisa Kit – 96 Wells Monobind, Inc. 1
Immulite® 2000 Systems PRL Prolactin Sample Diluent Siemens Healthcare Diagnostics Products GmbH 1
Vidas® Prolactin bioMerieux, Inc. 1

Showing 12 of 40. All products under Radioimmunoassay, Prolactin (Lactogen)

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Vitros
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Ortho-Clinical Diagnostics, Inc. UDI-DI 2022-03-25 Class II Device Design Falsely high or delayed patient and QC results may occur due to low end imprecision. VITROS Immunodiagnostic Products FSH, LH and Prol Reagents Low End Imprecision. Low-level quality control (QC) and patient samples at the low end of the Me 1767 units total: 1521 US; 246 OUS

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2018-07-12 Class II Device Design The recalling firm determined that biased results may occur for specific VITROS Immunodiagnostic Products (MicroWell Assays) at biotin concentrations which are lower than indicated in the current Instructions For Use (IFU). Patients who are 1790

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer