Nova Primary

Nova Primary is a laboratory system that measures glucose in lithium heparinized venous whole blood or plasma. The analyzer draws a 25 microliter sample from a syringe, blood collection…

Registry build 21.09.26

Nova Primary is a laboratory system that measures glucose in lithium heparinized venous whole blood or plasma. The analyzer draws a 25 microliter sample from a syringe, blood collection tube, microcentrifuge tube or sample cup.

Its replaceable sensor and membrane assembly use glucose oxidase to generate hydrogen peroxide from the sample. An electrode measures the resulting electrical current, which is proportional to glucose concentration. Results are reported as plasma equivalent glucose values.

Listed Item

Nova Primary Calibrator Cartridge 150 Sample

System Components and Readout

The system combines the analyzer, glucose sensor, membrane and calibrator cartridge, with an optional barcode scanner. For whole blood samples, an impedance based conductivity detector automatically adjusts the measurement to produce the plasma equivalent result. A color touchscreen provides the interface, and an onboard thermal printer produces a paper readout.

8manufacturers in China registered for this device type
8catalogue numbers in this listing
7510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Guangdong (3), Zhejiang (2), Jiangsu (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CGA
Manufacturer City Province Registered as Device types
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24
Flextronics Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 5
Yasee Biomedical Inc Qingdao Shandong Contract manufacturer 5
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Vivachek Biotech (Hangzhou) Co., Ltd. Hangzhou, Zhuji Zhejiang Contract manufacturer 21
Shenzhen Yuwen E-Commerce Co., Ltd. Shenzhen Guangdong Repacker / relabeller 19
Tianjin Empecs Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 8

Record

Regulatory record for Nova Primary
Listed by Nova Biomedical Corporation, United States
FDA product code CGA
Device type Glucose Oxidase, Glucose
Device class Class 2
Regulation 21 CFR 862.1345
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K203549
Record published 2023-02-09
Record revised 2026-04-13 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Storage environment temperature 15 to 30 °C

Catalogue Numbers

Catalogue numbers for Nova Primary
Catalogue number Size Per pack Status
Nova Primary Calibrator Cartridge 150 Sample In distribution
Nova Primary Ampuled Control 1, 2 20 In distribution
Nova Primary Calibrator Cartridge 450 Sample In distribution
Nova Primary Glucose Membrane 3 In distribution
Nova Primary Analyzer In distribution
Nova Primary Linearity Level 1 10 In distribution
Nova Primary Linearity Level 2 10 In distribution
Nova Primary Glucose Sensor In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
i-STAT Abbott Point OF Care Inc. 48
YSI Incorporated YSI Incorporated 34
Auvon Shenzhen Yuwen E-Commerce Co., Ltd. 28
Stat Profile Nova Biomedical Corporation 17
Fora Fora Care Inc. 13
TRUEtrack Trividia Health, Inc. 12
JAS Diagnostics Drew Scientific, Ltd. 11
StatStrip Nova Biomedical Corporation 9
Gluc-PAP Randox Laboratories Limited 8
Synermed® Infrared Laboratory Systems LLC 7
Prodigy No Coding Blood Glucose Test Strips Prodigy Diabetes Care, LLC 7
StatSensor/StatStrip Nova Biomedical Corporation 6

Showing 12 of 215. All products under Glucose Oxidase, Glucose

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K203549 2022-10-18
K200349 2020-03-13
K180340 2018-09-26
K070960 2007-07-11
K063821 2007-01-24
K060345 2006-04-28
K924743 1992-11-06

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2013-10-10 Class II Component design/selection Revised Battery Instructions for Removal and Expiration Date due to battery swelling and cell leakage est. 200,000 2014-03-24
2013-02-25 Class II Process design Glucose test strips reports no result message when tested 7433 cases 2014-09-26
2013-02-25 Class II Process design Glucose test strips reports no result message when tested 2200 cases 2014-09-26
2010-02-12 Not classified Nonconforming Material/Component Glucose strips report low glucose results 392 Cases (1800 strips each) 2011-07-22
2008-02-21 Not classified Component design/selection Lithium batteries may fail if the glucose or creatinine meters have been dropped. 4432 batteries 2008-10-28

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P990026 2002-02-04 CYGNUS GLUCOWATCH AUTOMATIC GLUCOSE BIOGRAPHER Animas Corp.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer