Pointe Scientific, Inc.
ISE Diluent, for the quantitative determination of sodium, potassium, and chloride in serum. Sodium measurements are used in the diagnosis and treatment of aldosteronism (excessive…
ISE Diluent, for the quantitative determination of sodium, potassium, and chloride in serum. Sodium measurements are used in the diagnosis and treatment of aldosteronism (excessive secretion of the hormone aldosterone), diabetes insipidus (chronic excretion of large amounts of dilute urine, accompanied by extreme thirst), adrenal hypertension, Addison’s disease (caused by destruction of the adrenal glands), dehydration, inappropriate antidiuretic hormone secretion, or other diseases involving electrolyte imbalance. Potassium measurements are used to monitor electrolyte balance in the diagnosis and treatment of disease conditions characterized by low or high blood potassium levels. Chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such as cystic fibrosis and diabetic acidosis. Size: 6 x 2L
Who Else Makes It
All of them in Guangdong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
Record
| Listed by | Horiba Instruments Incorporated, United States |
|---|---|
| FDA product code | CGZ |
| Device type | Electrode, Ion-Specific, Chloride |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1170 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K051646 |
| Record published | 2016-08-31 |
| Record revised | 2025-10-02 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 15 to 30 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| HI790-DIL | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stat Profile | Nova Biomedical Corporation | 14 |
| Nova | Nova Biomedical Corporation | 8 |
| Architect | Abbott Laboratories | 6 |
| Chloride Electrode | Roche Diagnostics Gmbh | 3 |
| Chloride Electrode | Medica Corp. | 3 |
| Chloride Electrode | Diamond Diagnostics Inc. | 3 |
| Vitros | Ortho-Clinical Diagnostics, Inc. | 2 |
| I.S.E. CL | Randox Laboratories Limited | 2 |
| Phoenix Diagnostics, Inc. | Phoenix Diagnostics, Inc. | 2 |
| Na/K/Cl Solution Pack | Medica Corp. | 2 |
| Ready Sensor™ Gold Reference Sensor Refill | Siemens Healthcare Diagnostics Inc | 1 |
| I.S.E. REF | Randox Laboratories Limited | 1 |
Showing 12 of 51. All products under Electrode, Ion-Specific, Chloride
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.