Cholesterol
Catalogue number 12-C7510-160, listed by Horiba Instruments Incorporated, United States, under Enzymatic Esterase--Oxidase, Cholesterol. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Zhejiang (4), Shandong (1), Guangxi (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Zhejiang Orient Gene Biotech | Huzhou | Zhejiang | Contract manufacturer | 86 |
| Biobase Biodustry(Shandong)Co., Ltd. | Jinan | Shandong | Manufacturer | 70 |
| Urit Medical Electronic Co., Ltd. | Guilin | Guangxi | Contract manufacturer | 28 |
| Shijiazhuang Hipro Biotechnology Co., Ltd. | Shijiazhuang | Hebei | Manufacturer | 22 |
| Hangzhou Lysun Biotechnology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 22 |
| Eaglenos Sciences, Inc. | Nanjing | Jiangsu | Manufacturer | 4 |
| Medicalsystem Biotechnology Co., Ltd. | Ningbo | Zhejiang | Manufacturer | 1 |
Record
| Listed by | Horiba Instruments Incorporated, United States |
|---|---|
| FDA product code | CHH |
| Device type | Enzymatic Esterase–Oxidase, Cholesterol |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1175 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K810673 |
| Record published | 2016-08-31 |
| Record revised | 2025-10-02 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 12-C7510-160 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Fora | Fora Care Inc. | 8 |
| Synermed® | Infrared Laboratory Systems LLC | 7 |
| JAS Diagnostics | Drew Scientific, Ltd. | 7 |
| Standard™ LipidoCare Lipid Test Strip – Lipid Profile | SD Biosensor, Inc. | 4 |
| Pointe Scientific, Inc. | Horiba Instruments Incorporated | 4 |
| Biobase | Biobase Biodustry(Shandong)Co., Ltd. | 4 |
| Carolina Liquid Chemistries Corp.® Cholesterol Reagent KIT BL211 | Carolina Liquid Chemistries | 4 |
| Cholesterol Gen.2 | Roche Diagnostics Gmbh | 3 |
| AU | Beckman Coulter, Inc. | 3 |
| Pointe Scientific, Inc. Cholesterol | Horiba Instruments Incorporated | 3 |
| Cholestech LDX™ | Alere San Diego, Inc. | 3 |
| Pointe Scientific Cholesterol (Liquid) | Horiba Instruments Incorporated | 3 |
Showing 12 of 77. All products under Enzymatic Esterase–Oxidase, Cholesterol
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-01-11 | Class II | Under Investigation by firm | N-Acetylcysteine (NAC) present in the blood of patients treated for paracetamol overdose can interfere with the Trinder reaction that uses hydrogen peroxide catalytic on aminoantipyrine and phenol, and can produce falsely low results with t | 216 | 2016-06-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.