Cholesterol
Catalogue number 08057443190, listed by Roche Diagnostics Gmbh, Germany, under Enzymatic Esterase--Oxidase, Cholesterol. 9 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Zhejiang (4), Shandong (1), Guangxi (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Zhejiang Orient Gene Biotech | Huzhou | Zhejiang | Contract manufacturer | 86 |
| Biobase Biodustry(Shandong)Co., Ltd. | Jinan | Shandong | Manufacturer | 70 |
| Urit Medical Electronic Co., Ltd. | Guilin | Guangxi | Contract manufacturer | 28 |
| Shijiazhuang Hipro Biotechnology Co., Ltd. | Shijiazhuang | Hebei | Manufacturer | 22 |
| Hangzhou Lysun Biotechnology Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 22 |
| Eaglenos Sciences, Inc. | Nanjing | Jiangsu | Manufacturer | 4 |
| Medicalsystem Biotechnology Co., Ltd. | Ningbo | Zhejiang | Manufacturer | 1 |
Record
| Listed by | Roche Diagnostics Gmbh, Germany |
|---|---|
| FDA product code | CHH |
| Device type | Enzymatic Esterase–Oxidase, Cholesterol |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1175 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K031824 |
| Record published | 2020-03-05 |
| Record revised | 2023-07-06 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 08057443190 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Fora | Fora Care Inc. | 8 |
| Synermed® | Infrared Laboratory Systems LLC | 7 |
| JAS Diagnostics | Drew Scientific, Ltd. | 7 |
| Standard™ LipidoCare Lipid Test Strip – Lipid Profile | SD Biosensor, Inc. | 4 |
| Pointe Scientific, Inc. | Horiba Instruments Incorporated | 4 |
| Biobase | Biobase Biodustry(Shandong)Co., Ltd. | 4 |
| Carolina Liquid Chemistries Corp.® Cholesterol Reagent KIT BL211 | Carolina Liquid Chemistries | 4 |
| Cholesterol Gen.2 | Roche Diagnostics Gmbh | 3 |
| AU | Beckman Coulter, Inc. | 3 |
| Pointe Scientific, Inc. Cholesterol | Horiba Instruments Incorporated | 3 |
| Cholestech LDX™ | Alere San Diego, Inc. | 3 |
| Pointe Scientific Cholesterol (Liquid) | Horiba Instruments Incorporated | 3 |
Showing 12 of 77. All products under Enzymatic Esterase–Oxidase, Cholesterol
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K051376 | 2005-08-23 |
| K031824 | 2003-07-09 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Roche Diagnostics Operations | 510(k) number | 2015-05-07 | Class II | Under Investigation by firm | Possible drug interference when using the Trinder reaction method on multiple Cobas Analyzers. Results of Trinder tests may be falsely decreased when the tests are run with urine samples (Creatinine plus and Uric Acid applications only) or | 6,255 analytical units distributed | 2017-03-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.