Synchron

Cholesterol Reagent (CHOL 2 x 300)

Registry build 21.09.26
9manufacturers in China registered for this device type
1catalogue number
4recalls on this code

Who Else Makes It

Concentrated in Zhejiang (4), Shandong (1), Guangxi (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code CHH
Manufacturer City Province Registered as Device types
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24
Zhejiang Orient Gene Biotech Huzhou Zhejiang Contract manufacturer 86
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Urit Medical Electronic Co., Ltd. Guilin Guangxi Contract manufacturer 28
Shijiazhuang Hipro Biotechnology Co., Ltd. Shijiazhuang Hebei Manufacturer 22
Hangzhou Lysun Biotechnology Co., Ltd. Hangzhou Zhejiang Manufacturer 22
Eaglenos Sciences, Inc. Nanjing Jiangsu Manufacturer 4
Medicalsystem Biotechnology Co., Ltd. Ningbo Zhejiang Manufacturer 1

Record

Regulatory record for Synchron
Listed by Beckman Coulter, Inc., United States
FDA product code CHH
Device type Enzymatic Esterase–Oxidase, Cholesterol
Device class Class 1
Regulation 21 CFR 862.1175
Establishment Contract manufacturer, Specification developer, Manufacturer, Exporter
Premarket notification Exempt
Record published 2016-08-24
Record revised 2023-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Synchron
Catalogue number Size Status
467825 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Fora Fora Care Inc. 8
Synermed® Infrared Laboratory Systems LLC 7
JAS Diagnostics Drew Scientific, Ltd. 7
Standard™ LipidoCare Lipid Test Strip – Lipid Profile SD Biosensor, Inc. 4
Pointe Scientific, Inc. Horiba Instruments Incorporated 4
Biobase Biobase Biodustry(Shandong)Co., Ltd. 4
Carolina Liquid Chemistries Corp.® Cholesterol Reagent KIT BL211 Carolina Liquid Chemistries 4
Cholesterol Gen.2 Roche Diagnostics Gmbh 3
AU Beckman Coulter, Inc. 3
Pointe Scientific, Inc. Cholesterol Horiba Instruments Incorporated 3
Cholestech LDX™ Alere San Diego, Inc. 3
Pointe Scientific Cholesterol (Liquid) Horiba Instruments Incorporated 3

Showing 12 of 77. All products under Enzymatic Esterase–Oxidase, Cholesterol

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Synchron
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Beckman Coulter, Inc. UDI-DI 2021-11-10 Class II Nonconforming Material/Component Cholesterol Reagent may fail with Out of Calibration Range Low (OCR Low) and/or Back to Back (B/B) errors. Low quality control recovery failures may be observed after passing calibration. Brown particulates in compartment C of the reagent c 1433

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-04-03 Class II Under Investigation by firm Beckman Coulter has identified the following drugs as potential sources of interference: Metamizole (Dipyrone), Sulfasalazine, and Sulfapyridine and may result in false low results. 128,718 units total (47,858 units in US) 2018-05-31
2016-04-13 Class II Device Design Beckman Coulter has identified that Dipyrone (Metamizole) may cause erroneous, false low results in the following assays: Cholesterol OSR6X16, Triglyceride OSR6X118, Uric Acid OSR6X98, Lactate OSR6X93, and Lipase OSR6X30. 43,877 units total (10,496 units in US) 2016-06-30
2014-12-15 Class II Under Investigation by firm N-Acetyl Cysteine (NAC), when administered in therapeutic concentrations for the treatment of acetaminophen overdose, interferes with the assays for these analytes: Cholesterol OSR6X16, Uric Acid OSR6X98, Lactate OSR6X93, and Lipase OSR6X30 59,965 units total (21,782 units in US) 2016-02-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer