Immulite®/Immulite® 1000 Systems E2 Estradiol
Catalogue number 10702832, listed by Siemens Healthcare Diagnostics Products GmbH, Germany, under Radioimmunoassay, Estradiol. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jilin (1), Hebei (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Shijiazhuang Hipro Biotechnology Co., Ltd. | Shijiazhuang | Hebei | Manufacturer | 22 |
| Shenzhen Yhlo Biotech Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 19 |
| Getein Biotech, Inc. | Nanjing | Jiangsu | Manufacturer | 19 |
| Beijing Hotgen Biotech Co., Ltd. | Beijing | Beijing | Manufacturer | 13 |
Record
| Listed by | Siemens Healthcare Diagnostics Products GmbH, Germany |
|---|---|
| FDA product code | CHP |
| Device type | Radioimmunoassay, Estradiol |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1260 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K932926 |
| Record published | 2020-09-24 |
| Record revised | 2025-10-16 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
| Distribution end date | 2025-09-30 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10702832 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Salimetrics | Salimetrics LLC. | 5 |
| MP Biomedicals LLC | Mp Biomedicals, LLC | 4 |
| 17beta-Estradiol Saliva Luminescence Immunoassay | IBL International Gmbh | 4 |
| Elecsys Estradiol III | Roche Diagnostics Gmbh | 3 |
| Alinity | Abbott Ireland | 3 |
| Advia Centaur® eE2 | Siemens Healthcare Diagnostics Inc | 3 |
| Architect | Abbott Ireland | 3 |
| Atellica IM eE2 | Siemens Healthcare Diagnostics Inc | 3 |
| Pantex | Pantex | 2 |
| Estradiol Sensitive Elisa | DRG Instruments Gesellschaft mit beschränkter Haftung | 2 |
| Salivary Estradiol Elisa | DRG Instruments Gesellschaft mit beschränkter Haftung | 2 |
| Ultrasensitive Estradiol Elisa | American Laboratory Products Company | 2 |
Showing 12 of 58. All products under Radioimmunoassay, Estradiol
Recalls Naming This Product
3 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Siemens Healthcare Diagnostics Inc | UDI-DI | 2020-02-05 | Class II | Under Investigation by firm | Due to high discordant Estradiol results which.potentially affects all patient populations, A falsely elevated estradiol level could lead a clinician to misinterpret a patient as pre-menopausal when truly post- menopausal. This may lead to | 2267 kits | 2021-11-18 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2016-01-13 | Class II | Device Design | The drug fulvestrant (Faslodex) may cause falsely elevated estradiol results. | 9251 units | 2018-01-08 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2016-01-13 | Class II | Device Design | The drug fulvestrant (Faslodex) may cause falsely elevated estradiol results. | 9334 units | 2018-01-08 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.