ABX Pentra AST CP
Catalogue number 1220001629, listed by Horiba ABX SAS, France, under Nadh Oxidation/Nad Reduction, Ast/Sgot. 2 manufacturers in China are registered for this product code.
2manufacturers in China registered for this device type
1catalogue number
1510(k) clearance
Who Else Makes It
Concentrated in Jilin (1), Shandong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Biobase Biodustry(Shandong)Co., Ltd. | Jinan | Shandong | Manufacturer | 70 |
Record
| Listed by | Horiba ABX SAS, France |
|---|---|
| FDA product code | CIT |
| Device type | Nadh Oxidation/Nad Reduction, Ast/Sgot |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1100 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K060318 |
| Record published | 2016-08-23 |
| Record revised | 2023-07-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1220001629 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Biobase | Biobase Biodustry(Shandong)Co., Ltd. | 19 |
| AST | Randox Laboratories Limited | 10 |
| JAS Diagnostics | Drew Scientific, Ltd. | 7 |
| Synermed® | Infrared Laboratory Systems LLC | 7 |
| Pointe Scientific, Inc. | Horiba Instruments Incorporated | 5 |
| AU | Beckman Coulter, Inc. | 4 |
| Architect | Abbott Ireland | 4 |
| Synchron | Beckman Coulter, Inc. | 4 |
| ACE | Alfa Wassermann | 4 |
| Architect | Abbott Medical | 3 |
| Alinity | Abbott Ireland | 3 |
| Architect | Abbott Laboratories | 3 |
Showing 12 of 62. All products under Nadh Oxidation/Nad Reduction, Ast/Sgot
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K060318 | 2006-08-08 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Horiba Instruments Incorporated | 510(k) number | 2012-10-10 | Class II | Software design | Horiba Medical is recalling the ABX PENTRA AST CP because during the AST application validation on the Pentra C200 using an Audit Systems linearity kit, it was determined that two higher values for AST (expected at 800 U/L and 1000 U/L) we | 66886 units | 2013-09-12 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.