AST/Sgot Liquid Reagent (Kinetic Method)

The AST/SGOT LIQUID REAGENT (KINETIC METHOD) is used for the quantitative determination of aspartate aminotransferase (AST) in human serum. The reagents are used in routine examination and…

Registry build 21.09.26

The AST/SGOT LIQUID REAGENT (KINETIC METHOD) is used for the quantitative determination of aspartate aminotransferase (AST) in human serum. The reagents are used in routine examination and monitoring of therapy and relapses.

2manufacturers in China registered for this device type
1catalogue number
1510(k) clearance

Who Else Makes It

Concentrated in Jilin (1), Shandong (1).

Chinese manufacturers registered for FDA product code CIT
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70

Record

Regulatory record for AST/Sgot Liquid Reagent (Kinetic Method)
Listed by Teco Diagnostics, United States
FDA product code CIT
Device type Nadh Oxidation/Nad Reduction, Ast/Sgot
Device class Class 2
Regulation 21 CFR 862.1100
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter
510(k) K981650
Record published 2023-07-20

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for AST/Sgot Liquid Reagent (Kinetic Method)
Catalogue number Size Status
A559-150 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Biobase Biobase Biodustry(Shandong)Co., Ltd. 19
AST Randox Laboratories Limited 10
JAS Diagnostics Drew Scientific, Ltd. 7
Synermed® Infrared Laboratory Systems LLC 7
Pointe Scientific, Inc. Horiba Instruments Incorporated 5
AU Beckman Coulter, Inc. 4
Architect Abbott Ireland 4
Synchron Beckman Coulter, Inc. 4
ACE Alfa Wassermann 4
Architect Abbott Medical 3
Alinity Abbott Ireland 3
Architect Abbott Laboratories 3

Showing 12 of 62. All products under Nadh Oxidation/Nad Reduction, Ast/Sgot

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K981650 1998-06-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer