RAPIDLab® 1200 Series 1265
RAPIDLab 1200 systems are intended for in vitro diagnostic use by healthcare professionals in the quantitative testing of human blood. The 1265 can determine pH, pCO2, pO2, Na+, K+, Ca++,…
RAPIDLab 1200 systems are intended for in vitro diagnostic use by healthcare professionals in the quantitative testing of human blood. The 1265 can determine pH, pCO2, pO2, Na+, K+, Ca++, Cl-, glucose, lactate, tHb, nBili, FO2Hb, FCOHb, FMetHb, FHHb parameters
Who Else Makes It
Registered in Guangdong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | JFP |
| Device type | Electrode, Ion Specific, Calcium |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1145 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K031560 |
| Record published | 2016-09-24 |
| Record revised | 2021-11-19 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | serial number |
| Storage | Special storage condition: Max 95% RH at 25’c; Handling environment temperature -25 to 45 °C; Storage environment temperature 4 to 45 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10321852 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stat Profile | Nova Biomedical Corporation | 9 |
| Nova | Nova Biomedical Corporation | 8 |
| Calcium Electrode | Medica Corp. | 2 |
| SC90 | Radiometer Medical APS | 2 |
| pH/pCO2/pO2/Na/K/Ca Analyzer | Medica Corp. | 2 |
| Na/K/Cl/Ca/Li Solution pack | Medica Corp. | 1 |
| Rinse Solution S4980 REF 944-130 | Radiometer Medical APS | 1 |
| Nova/Stat Profile | Nova Biomedical Corporation | 1 |
| Rapidpoint® 350 Sampler Module | Siemens Healthcare Diagnostics Inc | 1 |
| RAPIDLab® 1200 pH Electrode Fill | Siemens Healthcare Diagnostics Inc | 1 |
| Roche 9180 Electrolyte Analyzer | Roche Diagnostics Gmbh | 1 |
| E-Ca Cassette Carton | Opti Medical Systems Inc. | 1 |
Showing 12 of 33. All products under Electrode, Ion Specific, Calcium
Recalls Naming This Product
14 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2018-07-16 | Class II | Device Design | Therapeutic levels (1mg/mL and 2mg/mL) of Hydroxocobalamin may interfere with tHb and some of the CO-Ox fractions that are reported on the RAPIDPoint and RAPIDLab Blood Gas systems indicated. This may cause lower than expected values for ca | 138 | 2020-06-23 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2018-07-16 | Class II | Device Design | Therapeutic levels (1mg/mL and 2mg/mL) of Hydroxocobalamin may interfere with tHb and some of the CO-Ox fractions that are reported on the RAPIDPoint and RAPIDLab Blood Gas systems indicated. This may cause lower than expected values for ca | 2357 | 2020-06-23 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2017-04-10 | Class II | Software design | Potential Patient Demographic Error with Blank Patient ID Field | 159 units | 2019-08-20 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2016-08-11 | Class II | Software design | There is a potential for the first and/or last name of one patient to be printed with Patient ID and result data from a different patient, even though those fields have been turned Off for the system | 144 units | 2020-07-16 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2016-08-11 | Class II | Software design | There is a potential for the first and/or last name of one patient to be printed with Patient ID and result data from a different patient, even though those fields have been turned Off for the system | 197 units | 2020-07-16 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2015-05-06 | Class II | Software design | D50 and D51 Diagnostic error codes are not functional. | 122 devices | 2017-08-02 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2012-09-17 | Class II | Software Manufacturing/Software Deployment | RAPIDPoint 400 Series, RAPIDPoint 500, or RAPIDLab 1200 Series blood gas analyzer, users can inadvertently enter a wrong patient ID on the demographics screen, which ultimately could lead to a misidentification of the sample | 179 units | 2015-04-01 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2012-09-17 | Class II | Software Manufacturing/Software Deployment | RAPIDPoint 400 Series, RAPIDPoint 500, or RAPIDLab 1200 Series blood gas analyzer, users can inadvertently enter a wrong patient ID on the demographics screen, which ultimately could lead to a misidentification of the sample | 274 units | 2015-04-01 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2006-04-04 | Not classified | Software design | Invalid CO-oximeter values; Bayer HealthCare determined that under very specific conditions, the RapidLab 1245 or RapidLab 1265 systems may report invalid CO-oximeter values to an LIS, Rapidlink, or Rapidcomm data management system. | Domestic – 124 units, Foreign-364 units (all systems) | 2012-07-30 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2006-04-04 | Not classified | Software design | Invalid CO-oximeter values; Bayer HealthCare determined that under very specific conditions, the RapidLab 1245 or RapidLab 1265 systems may report invalid CO-oximeter values to an LIS, Rapidlink, or Rapidcomm data management system. | Domestic – 124 units, Foreign-364 units (all systems) | 2012-07-30 |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2006-01-20 | Not classified | Other | When stored data is recalled from memory, the results do not agree with the original results. Software anomaly: a calculation error occurs when using the correlation adjustment feature on the RapidLab 1200 Systems with software versions 1. | 2012-05-02 | |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2006-01-20 | Not classified | Other | When stored data is recalled from memory, the results do not agree with the original results. Software anomaly: a calculation error occurs when using the correlation adjustment feature on the RapidLab 1200 Systems with software versions 1. | 2012-05-02 | |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2006-01-20 | Not classified | Other | When stored data is recalled from memory, the results do not agree with the original results. Software anomaly: a calculation error occurs when using the correlation adjustment feature on the RapidLab 1200 Systems with software versions 1. | 2012-05-02 | |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2006-01-20 | Not classified | Other | When stored data is recalled from memory, the results do not agree with the original results. Software anomaly: a calculation error occurs when using the correlation adjustment feature on the RapidLab 1200 Systems with software versions 1. | 2012-05-02 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.