i-STAT
I-Stat Alinity Instrument (Model 500)
Who Else Makes It
All of them in Guangdong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
Record
| Listed by | Abbott Point OF Care Inc., United States |
|---|---|
| FDA product code | JGS |
| Device type | Electrode, Ion Specific, Sodium |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1665 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K153357 |
| Record published | 2021-10-12 |
| Record revised | 2023-09-11 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Latex | Contains natural rubber latex |
| Label carries | lot or batch number, expiry date, serial number |
| Storage | Storage environment temperature -10 to 50 °C |
| Packaging | Case of 25 |
| Distribution end date | 2023-08-31 |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 02R60-01 | In distribution | |
| 09P31-25 | In distribution | |
| 02R60-81 | In distribution | |
| 02R60-80 | In distribution | |
| 02R60-82 | In distribution | |
| 03P83-25 | In distribution | |
| 03P80-25 | In distribution | |
| 03P81-25 | Withdrawn | |
| 03P82-25 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stat Profile | Nova Biomedical Corporation | 13 |
| AU | Beckman Coulter, Inc. | 8 |
| GEM Premier ChemSTAT PAK Na+,K+,Ca++,Cl-, Glu, Crea, BUN, tCO2, Hct, Lac,pH,pCO2 | Instrumentation Laboratory SPA | 8 |
| Nova | Nova Biomedical Corporation | 6 |
| Phoenix Diagnostics, Inc. | Phoenix Diagnostics, Inc. | 5 |
| Sodium Electrode | Roche Diagnostics Gmbh | 4 |
| Pointe Scientific, Inc. | Horiba Instruments Incorporated | 3 |
| Architect | Abbott Laboratories | 3 |
| Synermed® | Infrared Laboratory Systems LLC | 3 |
| Sodium Electrode | Diamond Diagnostics Inc. | 3 |
| Phoenix Diagnostics | Phoenix Diagnostics, Inc. | 2 |
| Sodium Electrode | Medica Corp. | 2 |
Showing 12 of 88. All products under Electrode, Ion Specific, Sodium
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K230275 | 2023-10-27 |
| K183688 | 2020-02-07 |
| K153357 | 2016-07-08 |
Recalls Naming This Product
7 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Abbott Point OF Care Inc. | 510(k) number | 2011-02-15 | Not classified | Other | i-STAT CHEM 8+ cartridge may generate false results for sodium, chloride and hematocrit. | 6575 cartirdges | 2012-07-10 |
| Abbott Point OF Care Inc. | 510(k) number | 2007-10-18 | Not classified | Packaging change control | Difficult to Close — Certian lots of i-STAT cartridges are difficult to close, will not close or do not stay closed. | 2008-07-18 | |
| Abbott Point OF Care Inc. | 510(k) number | 2007-10-18 | Not classified | Packaging change control | Difficult to Close — Certain lots of i-STAT cartridges are difficult to close, will not close or do not stay closed. | 2008-07-18 | |
| Abbott Point OF Care Inc. | 510(k) number | 2007-10-18 | Not classified | Packaging change control | Difficult to Close — Certain lots of i-STAT cartridges are difficult to close, will not close or do not stay closed. | 2008-07-18 | |
| Abbott Point OF Care Inc. | 510(k) number | 2007-10-18 | Not classified | Packaging change control | Difficult to Close — Certain lots of i-STAT cartridges are difficult to close, will not close or do not stay closed. | 2008-07-18 | |
| Abbott Point OF Care Inc. | 510(k) number | 2007-10-18 | Not classified | Packaging change control | Difficult to Close — Certain lots of i-STAT cartridges are difficult to close, will not close or do not stay closed. | 2008-07-18 | |
| Abbott Point OF Care Inc. | 510(k) number | 2006-05-24 | Not classified | Other | Erroneous sodium and/or ionized calcium readings with a patient sample could be obtained | 59775 cartridges | 2007-08-15 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. 1 is recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2020-01-15 | Class II | No Marketing Application | The I-STAT BLUE CHEM8+ and CG4+ cartridges are not FDA cleared and do not have CLIA waived status. CLIA recognizes two types of laboratory tests: waived and non-waived. Different CLIA standards apply to waived and non-waived tests as well | 9,049,725 | 2021-03-02 |
| 2007-10-18 | Not classified | Packaging change control | Difficult to Close — Certain lots of i-STAT cartridges are difficult to close, will not close or do not stay closed. | 2008-07-18 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability.
Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.