Dimension EXL Tnih Calibrator

LOCI High-Sensitivity Troponin Calibrator

Registry build 21.09.26
1manufacturer
1catalogue number
11510(k) clearances naming this product code
17recalls on this code

Who Else Makes It

Registered in Jiangsu.

Chinese manufacturers registered for FDA product code JIT
Manufacturer City Province Registered as Device types
Beckman Coulter Laboratory Systems (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 4

Record

Regulatory record for Dimension EXL Tnih Calibrator
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code JIT
Device type Calibrator, Secondary
Device class Class 2
Regulation 21 CFR 862.1150
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2019-10-16
Record revised 2021-11-18 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, expiry date
Storage Storage environment temperature -25 to -15 °C

Catalogue Numbers

Catalogue numbers for Dimension EXL Tnih Calibrator
Catalogue number Size Per pack Status
10719483 2 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Vitros Ortho-Clinical Diagnostics, Inc. 39
Exact Diagnostics Exact Diagnostics 30
Architect Abbott Medical 26
Architect Abbott Ireland 24
Alinity Abbott Medical 18
Alinity Abbott Ireland 16
Architect Abbott Laboratories 15
Architect Abbott Ireland Diagnostics 11
Alinity Abbott Ireland Diagnostics 11
JAS Diagnostics Drew Scientific, Ltd. 10
BioPlex 2200 Bio-Rad Laboratories Inc. 8
AU Beckman Coulter, Inc. 6

Showing 12 of 391. All products under Calibrator, Secondary

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K162538 2016-11-17
K130698 2013-04-05
K113373 2011-12-30
K103548 2011-06-02
K110169 2011-04-07
K103836 2011-02-16
K083462 2009-02-27
K082680 2008-10-10
K081789 2008-09-10
K081319 2008-08-04
K081683 2008-07-07

Recalls

14 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. 2 are recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-07-25 Class II Under Investigation by firm There is a potential for ADVIA Chemistry Urinary/Cerebrospinal Fluid Protein reagent carryover impacting Enzymatic Creatinine_2 (ECRE_2). Falsely depressed ECRE_2 results may be observed when the assay is processed after the UCFP test on AD 3067 units
2020-09-22 Class II Device Design Fructosamine QC and patient samples may exhibit a 60 umol/L positive bias across the measuring range compared to predicate assay reference leading to a potential adjustment of hyperglycemic therapy. Positively biased fructosamine results ma US: 23 units; OUS: 204 units
2020-09-22 Class II Device Design Fructosamine QC and patient samples may exhibit a 60 umol/L positive bias across the measuring range compared to predicate assay reference leading to a potential adjustment of hyperglycemic therapy. Positively biased fructosamine results ma US: 28; OUS: 255 units
2018-09-26 Class II Software design Multiple Issues Identified in Atellica Solution System Software in V 1.14.2 and lower in: Atellica IM 1300 Analyzer
Atellica IM 1600 Analyzer;Atellica CH 930 Analyzer;
Atellica Sample Handler Prime
217 units 2020-06-24
2018-09-26 Class II Software design Multiple Issues Identified in Atellica Solution System Software in V 1.14.2 and lower in: Atellica IM 1300 Analyzer
Atellica IM 1600 Analyzer;Atellica CH 930 Analyzer;
Atellica Sample Handler Prime
490 units 2020-06-24
2018-09-26 Class II Software design Multiple Issues Identified in Atellica Solution System Software in V 1.14.2 and lower in: Atellica IM 1300 Analyzer
Atellica IM 1600 Analyzer;Atellica CH 930 Analyzer;
Atellica Sample Handler Prime
410 units 2020-06-24
2018-09-26 Class II Software design Multiple Issues Identified in Atellica Solution System Software in V 1.14.2 and lower in: Atellica IM 1300 Analyzer
Atellica IM 1600 Analyzer;Atellica CH 930 Analyzer;
Atellica Sample Handler Prime
264 2020-06-24
2017-04-05 Class II Nonconforming Material/Component Current lots of ADVIA Centaur/XP/XPT/CP Insulin (IRI) assay recover approximately 40% higher than the World Health Organization (WHO) 1st IRP 66/304 standardization based on slope values. Other performance characteristics are being met per 2019-04-02
2016-05-05 Class III Under Investigation by firm Complaints of positive shift of patient and QC results when the ALTI assay is calibrated with the Dimension Enzyme II calibrator. Internal investigation has confirmed that patient samples and QC material demonstrate a shift of up to 10% in 24,940.00 2018-02-02
2014-11-24 Class II Under Investigation by firm Dimension Vista Myoglobin Calibrator (MYO CAL) may produce a positive shift in MYO QC and Patient test results that exceeds acceptance criteria for this product. A positive shift observed up to 12% at MYO concentrations within and above the 1230 2016-12-13
2014-08-28 Class II Process design Siemens Healthcare Diagnostics has determined that Dimension Vista® Mass CKMB Isoenzyme Calibrator (MMB CAL) shows drift during routine stability monitoring that exceeds our acceptance criteria for drift over the shelf life of this product. 6562 2015-03-30
2013-09-17 Class II Process control Siemens Dimension LOCI TNI Troponin I calibrator lot 3DD007 may demonstrate an average upward shift of 24% in QC and patient results following calibration. 1625 2014-08-27
2013-06-05 Class II Material/Component Contamination Siemens Healthcare Diagnostics has received complaints that the lyophilized cake is not fully dissolved after the stated time in the MMB calibrator Instructions For Use (IFU). The frequency of this occurrence is low but if it occurs, gel-l 7,470 2015-03-18
2013-05-14 Class II No Marketing Application iPTH Assay- reagent and calibrator lots may have demonstrated higher than anticipated variability 99 (2 pk) 2015-03-05
2013-05-14 Class II No Marketing Application iPTH Assay- reagent and calibrator lots may have demonstrated higher than anticipated variability 198 (6 pk) 2015-03-05
2012-10-10 Class III Nonconforming Material/Component Correlation slope bias and accuracy shift 1985 cartons 2014-01-08
2011-11-17 Not classified Nonconforming Material/Component Siemens Healthcare Diagnostics has confirmed positive bias on QC and Patients. 2281 cartons 2014-08-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.