Fruc CAL

This product is intended for in vitro diagnostic use in the calibration of the Randox Liquid Fructosamine assay on clinical chemistry systems.

Registry build 21.09.26
1manufacturer
1catalogue number
1510(k) clearance
2recalls on this code

Who Else Makes It

Registered in Jiangsu.

Chinese manufacturers registered for FDA product code JIT
Manufacturer City Province Registered as Device types
Beckman Coulter Laboratory Systems (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 4

Record

Regulatory record for Fruc CAL
Listed by Randox Laboratories Limited, United Kingdom
FDA product code JIT
Device type Calibrator, Secondary
Device class Class 2
Regulation 21 CFR 862.1150
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer
510(k) K023763
Record published 2016-09-24
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Special storage condition: Once reconstituted the calibrator is stable for 28 days at +2oC to +8oC, and 1 month at → 20oC when frozen once.; Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for Fruc CAL
Catalogue number Size Status
FR2993 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Vitros Ortho-Clinical Diagnostics, Inc. 39
Exact Diagnostics Exact Diagnostics 30
Architect Abbott Medical 26
Architect Abbott Ireland 24
Alinity Abbott Medical 18
Alinity Abbott Ireland 16
Architect Abbott Laboratories 15
Architect Abbott Ireland Diagnostics 11
Alinity Abbott Ireland Diagnostics 11
JAS Diagnostics Drew Scientific, Ltd. 10
BioPlex 2200 Bio-Rad Laboratories Inc. 8
AU Beckman Coulter, Inc. 6

Showing 12 of 391. All products under Calibrator, Secondary

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K142181 2014-09-18

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Fruc CAL
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Randox Laboratories Limited 510(k) number 2018-12-03 Class II Under Investigation by firm The firm is conducting a Device Modification for Fructosamine Calibrator, Fructosamine Control 1 and Control 3 for the lots specified. The assigned value of Fructosamine in this calibrator and controls has now been re-assigned by a decrease 85 kits

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2024-01-31 Class II Under Investigation by firm Microalbumin Calibrator Series, MA1567 & MA2426, is running with a negative bias compared to other methods and may misclassify patient results. Users may experience a shift in Quality Control and patient sample recovery of up to +12%. 8 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer