Alinity

Alinity c Clinical Chemistry Calibrator Kit

Registry build 21.09.26
3manufacturers in China registered for this device type
3catalogue numbers in this listing
3510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jilin (1), Guangdong (1), Jiangsu (1).

Chinese manufacturers registered for FDA product code JIX
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Getein Biotech, Inc. Nanjing Jiangsu Manufacturer 19

Record

Regulatory record for Alinity
Listed by Abbott Laboratories, United States
FDA product code JIX
Device type Calibrator, Multi-Analyte Mixture
Device class Class 2
Regulation 21 CFR 862.1150
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2018-08-08
Record revised 2024-02-21 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Handling environment temperature up to 30 °C; Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for Alinity
Catalogue number Size Status
08P6503 In distribution
08P6702 In distribution
08P6601 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Stat Profile Nova Biomedical Corporation 54
BioPlex 2200 Bio-Rad Laboratories Inc. 32
Plasma Calibrator Set Chromsystems Instruments & Chemicals Gmbh 22
Phoenix Diagnostics Phoenix Diagnostics, Inc. 20
Nova Nova Biomedical Corporation 15
Plasma Calibration Standard Chromsystems Instruments & Chemicals Gmbh 15
Phoenix Diagnostics, Inc. Phoenix Diagnostics, Inc. 15
Architect Abbott Laboratories 11
Alinity Abbott Medical 10
Synchron Beckman Coulter, Inc. 9
Architect Abbott Medical 9
Urine Calibration Standard Chromsystems Instruments & Chemicals Gmbh 8

Showing 12 of 229. All products under Calibrator, Multi-Analyte Mixture

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K123372 2013-01-14
K103403 2011-02-04
K981706 1998-07-09

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2008-09-12 Not classified Component design/selection The field action was initiated after an investigation for the Total Bilirubin reagents (List Number 8G62 and List Number 6L45) determined that the matrix of the secondary standard used in the value assignment of the calibrator is sensitive 7,101 units worldwide (2,267 units in US). 2012-04-24
2008-04-24 Not classified Error in labeling An incorrect Magnesium calibrator 2 value (CAL 2) was provided for Clinical Chemistry Iron/Magnesium Calibrator lot number 54187M200. Use of the incorrect Magnesium CAL 2 value causes quality control and patient magnesium results to be re 1287 2009-07-09
2007-08-10 Not classified Material/Component Contamination Incorrect Calibrator values: changes in a raw material used in the Bilirubin Calibrator value assignment process contributed to variability in the preparation of the standard. 7,033 units total worldwide 2012-04-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer