| 2023-10-26 | Class II | Under Investigation by firm | RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter | 6611 cartridges US | |
| 2023-10-26 | Class II | Under Investigation by firm | RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter | 6035 cartridges US | |
| 2023-10-26 | Class II | Under Investigation by firm | RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter | 3505 Cartridges US | |
| 2023-10-26 | Class II | Under Investigation by firm | RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter | 0 cartridges US | |
| 2019-11-19 | Class II | No Marketing Application | Atellica and ADVIA hsCRP calibrator accuracy has drifted away from the reference materials (ERM-DA470/IFCC), which is causing a high bias on QC and patient sample recovery. | 844 | 2021-08-30 |
| 2019-11-19 | Class II | No Marketing Application | Atellica CH: The Atellica CH High Sensitivity CReactive Protein Calibrator (hsCRP CAL) is for in vitro diagnostic use in calibrating the hsCRP assay using the Atellica CH Analyzer. | 1306 | 2021-08-30 |
| 2017-11-09 | Class II | Under Investigation by firm | An increase in the number of failed calibration events or negative bias with Quality Control (QC) and patient samples when using Dimension Vista LOCI 8 Calibrator lot 7CD076 to calibrate Estradiol (E2) Assay. | 989 (681 USA/308 OUS) | 2020-06-08 |
| 2016-09-15 | Class II | Under Investigation by firm | Siemens determined that discrepant low calcium recovery of QC and patient samples can occur with Dimension Vista CHEM 1 CAL lots 5GM081 and 5GM082. | 9,935 units | 2018-05-31 |
| 2016-05-05 | Class III | Under Investigation by firm | Complaints of positive shift of patient and QC results when the ALTI assay is calibrated with the Dimension Vista Enzyme 2 calibrator. Internal investigation has confirmed that patient samples and QC material demonstrate a shift of up to 1 | 13,147 units | 2018-02-02 |
| 2016-02-04 | Class II | Under Investigation by firm | ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay | 519 pack | 2017-08-01 |
| 2016-02-04 | Class II | Under Investigation by firm | ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay | 15224 (2-pack) | 2017-08-01 |
| 2016-02-04 | Class II | Under Investigation by firm | ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay | 6455 (6 pack) | 2017-08-01 |
| 2015-01-19 | Class II | Device Design | Incorrect calibrator lot values were assigned for ADVIA Chemistry Systems Drug Calibrator I, lot 3JD018, for the ADVIA Chemistry Systems Phenytoin 2 (PHNY_2) and Phenobarbital 2 (PHNB_2) assays which was the result of calibrator value misca | 657 | 2015-09-21 |
| 2014-09-26 | Class II | Device Design | Positive bias for Calibrator E lot kits ending in 38 and 39 with the ADVIA Centaur Systems Cortisol and Progesterone assays compared to the respective master curves. | Total = 19,352 (13,881 – 2 pack, 4878 – 6 pack, 593 – 6 pack | 2016-01-29 |
| 2014-08-18 | Class II | Process design | Siemens Healthcare Diagnostics has received complaints for low recovery of Magnesium (MG) Quality Control (QC) and patient samples following calibration of MG with the Dimension Vista® CHEM 1 CAL, lot 3GM081. Investigation by Siemens conf | 9769 Total (6000 US) | 2015-02-02 |
| 2014-08-06 | Class II | Software design | The ADVIA Chemistry Systems A1c_3 method may exhibit a percent bias of -9% to +11% for hemoglobin (Hb)A1c samples when using A1c_3 Calibrator lots 3HD044 and 3LD068. Depending on quality control limits, this issue may not have been detecte | Domestic: 1122 kits; Foreign: 236 kits | 2017-02-28 |
| 2014-01-06 | Class II | Nonconforming Material/Component | Complaints were received regarding Quality Control (QC) shifts with Pseudocholinesterase (PCHE) and imprecision during PCHE calibration with the Dimension Vista Enzyme 1 Calibrator (ENZ 1 CAL). | 3496 | 2015-05-06 |
| 2010-02-26 | Not classified | Employee error | There is incorrect barcode information, which can potentially cause the Alert Message “Calibrator Insert Missing” to be displayed. | 1310 cartons | 2010-10-13 |
| 2009-10-23 | Not classified | Other | patient results are depressed | 1753 cartons | 2010-06-22 |
| 2009-08-31 | Not classified | Other | Siemens Healthcare Diagnostics, Inc. has confirmed high accuracy shifts with Dimension Vista URCA Flex reagent cartridge (various lots) when calibrating with some vials from CHEM 1 calibrator lot 9DM001. | 1474 Cartons | 2010-12-13 |