Atellica CH LSP Calibrator

Liquid Specific Protein (LSP) Calibrator Atellica CH - CAL 6 x 1 x 1.0mL

Registry build 21.09.26
3manufacturers in China registered for this device type
1catalogue number
12510(k) clearances naming this product code
20recalls on this code

Who Else Makes It

Concentrated in Jilin (1), Guangdong (1), Jiangsu (1).

Chinese manufacturers registered for FDA product code JIX
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Getein Biotech, Inc. Nanjing Jiangsu Manufacturer 19

Record

Regulatory record for Atellica CH LSP Calibrator
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code JIX
Device type Calibrator, Multi-Analyte Mixture
Device class Class 2
Regulation 21 CFR 862.1150
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K103701
Record published 2017-12-27
Record revised 2021-11-18 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for Atellica CH LSP Calibrator
Catalogue number Size Status
11099434 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Stat Profile Nova Biomedical Corporation 54
BioPlex 2200 Bio-Rad Laboratories Inc. 32
Plasma Calibrator Set Chromsystems Instruments & Chemicals Gmbh 22
Phoenix Diagnostics Phoenix Diagnostics, Inc. 20
Nova Nova Biomedical Corporation 15
Plasma Calibration Standard Chromsystems Instruments & Chemicals Gmbh 15
Phoenix Diagnostics, Inc. Phoenix Diagnostics, Inc. 15
Architect Abbott Laboratories 11
Alinity Abbott Medical 10
Synchron Beckman Coulter, Inc. 9
Architect Abbott Medical 9
Urine Calibration Standard Chromsystems Instruments & Chemicals Gmbh 8

Showing 12 of 229. All products under Calibrator, Multi-Analyte Mixture

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K153365 2015-12-18
K140790 2015-06-15
K123321 2013-02-15
K122398 2012-10-12
K103701 2011-02-18
K103612 2011-01-25
K101460 2010-07-09
K100778 2010-05-05
K093732 2010-03-22
K093645 2010-03-05
K083579 2009-02-20
K081103 2008-05-23

Recalls

16 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. 2 are recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-10-26 Class II Under Investigation by firm RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter 6611 cartridges US
2023-10-26 Class II Under Investigation by firm RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter 6035 cartridges US
2023-10-26 Class II Under Investigation by firm RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter 3505 Cartridges US
2023-10-26 Class II Under Investigation by firm RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter 0 cartridges US
2019-11-19 Class II No Marketing Application Atellica and ADVIA hsCRP calibrator accuracy has drifted away from the reference materials (ERM-DA470/IFCC), which is causing a high bias on QC and patient sample recovery. 844 2021-08-30
2019-11-19 Class II No Marketing Application Atellica CH: The Atellica CH High Sensitivity CReactive Protein Calibrator (hsCRP CAL) is for in vitro diagnostic use in calibrating the hsCRP assay using the Atellica CH Analyzer. 1306 2021-08-30
2017-11-09 Class II Under Investigation by firm An increase in the number of failed calibration events or negative bias with Quality Control (QC) and patient samples when using Dimension Vista LOCI 8 Calibrator lot 7CD076 to calibrate Estradiol (E2) Assay. 989 (681 USA/308 OUS) 2020-06-08
2016-09-15 Class II Under Investigation by firm Siemens determined that discrepant low calcium recovery of QC and patient samples can occur with Dimension Vista CHEM 1 CAL lots 5GM081 and 5GM082. 9,935 units 2018-05-31
2016-05-05 Class III Under Investigation by firm Complaints of positive shift of patient and QC results when the ALTI assay is calibrated with the Dimension Vista Enzyme 2 calibrator. Internal investigation has confirmed that patient samples and QC material demonstrate a shift of up to 1 13,147 units 2018-02-02
2016-02-04 Class II Under Investigation by firm ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay 519 pack 2017-08-01
2016-02-04 Class II Under Investigation by firm ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay 15224 (2-pack) 2017-08-01
2016-02-04 Class II Under Investigation by firm ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay 6455 (6 pack) 2017-08-01
2015-01-19 Class II Device Design Incorrect calibrator lot values were assigned for ADVIA Chemistry Systems Drug Calibrator I, lot 3JD018, for the ADVIA Chemistry Systems Phenytoin 2 (PHNY_2) and Phenobarbital 2 (PHNB_2) assays which was the result of calibrator value misca 657 2015-09-21
2014-09-26 Class II Device Design Positive bias for Calibrator E lot kits ending in 38 and 39 with the ADVIA Centaur Systems Cortisol and Progesterone assays compared to the respective master curves. Total = 19,352 (13,881 – 2 pack, 4878 – 6 pack, 593 – 6 pack 2016-01-29
2014-08-18 Class II Process design Siemens Healthcare Diagnostics has received complaints for low recovery of Magnesium (MG) Quality Control (QC) and patient samples following calibration of MG with the Dimension Vista® CHEM 1 CAL, lot 3GM081. Investigation by Siemens conf 9769 Total (6000 US) 2015-02-02
2014-08-06 Class II Software design The ADVIA Chemistry Systems A1c_3 method may exhibit a percent bias of -9% to +11% for hemoglobin (Hb)A1c samples when using A1c_3 Calibrator lots 3HD044 and 3LD068. Depending on quality control limits, this issue may not have been detecte Domestic: 1122 kits; Foreign: 236 kits 2017-02-28
2014-01-06 Class II Nonconforming Material/Component Complaints were received regarding Quality Control (QC) shifts with Pseudocholinesterase (PCHE) and imprecision during PCHE calibration with the Dimension Vista Enzyme 1 Calibrator (ENZ 1 CAL). 3496 2015-05-06
2010-02-26 Not classified Employee error There is incorrect barcode information, which can potentially cause the Alert Message “Calibrator Insert Missing” to be displayed. 1310 cartons 2010-10-13
2009-10-23 Not classified Other patient results are depressed 1753 cartons 2010-06-22
2009-08-31 Not classified Other Siemens Healthcare Diagnostics, Inc. has confirmed high accuracy shifts with Dimension Vista URCA Flex reagent cartridge (various lots) when calibrating with some vials from CHEM 1 calibrator lot 9DM001. 1474 Cartons 2010-12-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer