Pointe Chemistry Calibrator Set
The Multi-Analyte Chemistry calibrator is for use as a calibrator of Pointe Scientific Inc. clinical chemistry assays. This calibrator material is well suited for automated and…
The Multi-Analyte Chemistry calibrator is for use as a calibrator of Pointe Scientific Inc. clinical chemistry assays. This calibrator material is well suited for automated and semi-automated analytical procedures.
Who Else Makes It
Concentrated in Jilin (1), Guangdong (1), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Getein Biotech, Inc. | Nanjing | Jiangsu | Manufacturer | 19 |
Record
| Listed by | Horiba Instruments Incorporated, United States |
|---|---|
| FDA product code | JIX |
| Device type | Calibrator, Multi-Analyte Mixture |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1150 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K070207 |
| Record published | 2026-05-01 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| C7506-15 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stat Profile | Nova Biomedical Corporation | 54 |
| BioPlex 2200 | Bio-Rad Laboratories Inc. | 32 |
| Plasma Calibrator Set | Chromsystems Instruments & Chemicals Gmbh | 22 |
| Phoenix Diagnostics | Phoenix Diagnostics, Inc. | 20 |
| Nova | Nova Biomedical Corporation | 15 |
| Plasma Calibration Standard | Chromsystems Instruments & Chemicals Gmbh | 15 |
| Phoenix Diagnostics, Inc. | Phoenix Diagnostics, Inc. | 15 |
| Architect | Abbott Laboratories | 11 |
| Alinity | Abbott Medical | 10 |
| Synchron | Beckman Coulter, Inc. | 9 |
| Architect | Abbott Medical | 9 |
| Urine Calibration Standard | Chromsystems Instruments & Chemicals Gmbh | 8 |
Showing 12 of 229. All products under Calibrator, Multi-Analyte Mixture
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2014-01-20 | Class II | Under Investigation by firm | HORIBA Medical is informing all ABX PENTRA MultiCal, N Control, and P Control customers running the Creatinine Rate Blank Method assay on the ABX PENTRA 400 and PC200 that the Target Values for Creatinine Rate Blank Method have been updated | 2,023 units | 2014-12-05 |
| 2006-06-09 | Not classified | Other | Open vial stability-Potential microbial growth in the alcohol standard and possible unexpected QC changes in the ammonia portion of the control due to the lack of validation for long-term open vial stability. | 108 units | 2007-11-20 |
| 2006-06-09 | Not classified | Other | Open vial stability-Potential microbial growth in the alcohol standard and possible unexpected QC changes in the ammonia portion of the control due to the lack of validation for long-term open vial stability. | 44 units | 2007-11-20 |
| 2006-06-09 | Not classified | Other | Open vial stability-Potential microbial growth in the alcohol standard and possible unexpected QC changes in the ammonia portion of the control due to the lack of validation for long-term open vial stability. | 98 units | 2007-11-20 |
| 2006-06-09 | Not classified | Other | Open vial stability-Potential microbial growth in the alcohol standard and possible unexpected QC changes in the ammonia portion of the control due to the lack of validation for long-term open vial stability. | 5 units | 2007-11-20 |
| 2006-06-09 | Not classified | Other | Open vial stability-Potential microbial growth in the alcohol standard and possible unexpected QC changes in the ammonia portion of the control due to the lack of validation for long-term open vial stability. | 44 units | 2007-11-20 |
| 2006-06-09 | Not classified | Other | Open vial stability-Potential microbial growth in the alcohol standard and possible unexpected QC changes in the ammonia portion of the control due to the lack of validation for long-term open vial stability. | 98 units | 2007-11-20 |
| 2006-06-09 | Not classified | Other | Open vial stability-Potential microbial growth in the alcohol standard and possible unexpected QC changes in the ammonia portion of the control due to the lack of validation for long-term open vial stability. | 44 units | 2007-11-20 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.