RAPIDPoint® 500 Measurement Cartridge
RAPIDPoint® 500 Measurement Cartridge (250 tests) - pH, pCO2, pO2, Na+, Ca++, Cl-, K+, Glu, Lac, tHb, FO2Hb, FHHb, FCOHb, FMetHb, nBili is an in vitro diagnostics device which is intended…
RAPIDPoint® 500 Measurement Cartridge (250 tests) – pH, pCO2, pO2, Na+, Ca++, Cl-, K+, Glu, Lac, tHb, FO2Hb, FHHb, FCOHb, FMetHb, nBili is an in vitro diagnostics device which is intended to be used on the RAPIDPoint® 500 analyzer.
Who Else Makes It
Concentrated in Jilin (1), Guangdong (1), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Getein Biotech, Inc. | Nanjing | Jiangsu | Manufacturer | 19 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | JIX |
| Device type | Calibrator, Multi-Analyte Mixture |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1150 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K122398 |
| Record published | 2016-09-24 |
| Record revised | 2021-11-19 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | expiry date, serial number |
| Storage | Handling environment temperature 2 to 25 °C; Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10844813 | In distribution | |
| 10491447 | In distribution | |
| 10491449 | In distribution | |
| 10491448 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stat Profile | Nova Biomedical Corporation | 54 |
| BioPlex 2200 | Bio-Rad Laboratories Inc. | 32 |
| Plasma Calibrator Set | Chromsystems Instruments & Chemicals Gmbh | 22 |
| Phoenix Diagnostics | Phoenix Diagnostics, Inc. | 20 |
| Nova | Nova Biomedical Corporation | 15 |
| Plasma Calibration Standard | Chromsystems Instruments & Chemicals Gmbh | 15 |
| Phoenix Diagnostics, Inc. | Phoenix Diagnostics, Inc. | 15 |
| Architect | Abbott Laboratories | 11 |
| Alinity | Abbott Medical | 10 |
| Synchron | Beckman Coulter, Inc. | 9 |
| Architect | Abbott Medical | 9 |
| Urine Calibration Standard | Chromsystems Instruments & Chemicals Gmbh | 8 |
Showing 12 of 229. All products under Calibrator, Multi-Analyte Mixture
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K153365 | 2015-12-18 |
| K140790 | 2015-06-15 |
| K123321 | 2013-02-15 |
| K122398 | 2012-10-12 |
| K103701 | 2011-02-18 |
| K103612 | 2011-01-25 |
| K101460 | 2010-07-09 |
| K100778 | 2010-05-05 |
| K093732 | 2010-03-22 |
| K093645 | 2010-03-05 |
| K083579 | 2009-02-20 |
| K081103 | 2008-05-23 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2023-10-26 | Class II | Under Investigation by firm | RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter | 0 cartridges US |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2023-10-26 | Class II | Under Investigation by firm | RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter | 6035 cartridges US |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2023-10-26 | Class II | Under Investigation by firm | RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter | 6611 cartridges US |
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2023-10-26 | Class II | Under Investigation by firm | RAPIDPoint 500 Systems Measurement Cartridges (with lactate) has the potential to affect the Sodium (Na+) sensor to produce a negative bias that could result in serious injury due to a delayed diagnosis of hypernatremia or unnecessary inter | 3505 Cartridges US |
Recalls
12 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. 2 are recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2019-11-19 | Class II | No Marketing Application | Atellica and ADVIA hsCRP calibrator accuracy has drifted away from the reference materials (ERM-DA470/IFCC), which is causing a high bias on QC and patient sample recovery. | 844 | 2021-08-30 |
| 2019-11-19 | Class II | No Marketing Application | Atellica CH: The Atellica CH High Sensitivity CReactive Protein Calibrator (hsCRP CAL) is for in vitro diagnostic use in calibrating the hsCRP assay using the Atellica CH Analyzer. | 1306 | 2021-08-30 |
| 2017-11-09 | Class II | Under Investigation by firm | An increase in the number of failed calibration events or negative bias with Quality Control (QC) and patient samples when using Dimension Vista LOCI 8 Calibrator lot 7CD076 to calibrate Estradiol (E2) Assay. | 989 (681 USA/308 OUS) | 2020-06-08 |
| 2016-09-15 | Class II | Under Investigation by firm | Siemens determined that discrepant low calcium recovery of QC and patient samples can occur with Dimension Vista CHEM 1 CAL lots 5GM081 and 5GM082. | 9,935 units | 2018-05-31 |
| 2016-05-05 | Class III | Under Investigation by firm | Complaints of positive shift of patient and QC results when the ALTI assay is calibrated with the Dimension Vista Enzyme 2 calibrator. Internal investigation has confirmed that patient samples and QC material demonstrate a shift of up to 1 | 13,147 units | 2018-02-02 |
| 2016-02-04 | Class II | Under Investigation by firm | ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay | 519 pack | 2017-08-01 |
| 2016-02-04 | Class II | Under Investigation by firm | ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay | 15224 (2-pack) | 2017-08-01 |
| 2016-02-04 | Class II | Under Investigation by firm | ADVIA Centaur Systems Calibrator E Lot 42 and 43 Bias with the Testosterone Assay | 6455 (6 pack) | 2017-08-01 |
| 2015-01-19 | Class II | Device Design | Incorrect calibrator lot values were assigned for ADVIA Chemistry Systems Drug Calibrator I, lot 3JD018, for the ADVIA Chemistry Systems Phenytoin 2 (PHNY_2) and Phenobarbital 2 (PHNB_2) assays which was the result of calibrator value misca | 657 | 2015-09-21 |
| 2014-09-26 | Class II | Device Design | Positive bias for Calibrator E lot kits ending in 38 and 39 with the ADVIA Centaur Systems Cortisol and Progesterone assays compared to the respective master curves. | Total = 19,352 (13,881 – 2 pack, 4878 – 6 pack, 593 – 6 pack | 2016-01-29 |
| 2014-08-18 | Class II | Process design | Siemens Healthcare Diagnostics has received complaints for low recovery of Magnesium (MG) Quality Control (QC) and patient samples following calibration of MG with the Dimension Vista® CHEM 1 CAL, lot 3GM081. Investigation by Siemens conf | 9769 Total (6000 US) | 2015-02-02 |
| 2014-08-06 | Class II | Software design | The ADVIA Chemistry Systems A1c_3 method may exhibit a percent bias of -9% to +11% for hemoglobin (Hb)A1c samples when using A1c_3 Calibrator lots 3HD044 and 3LD068. Depending on quality control limits, this issue may not have been detecte | Domestic: 1122 kits; Foreign: 236 kits | 2017-02-28 |
| 2014-01-06 | Class II | Nonconforming Material/Component | Complaints were received regarding Quality Control (QC) shifts with Pseudocholinesterase (PCHE) and imprecision during PCHE calibration with the Dimension Vista Enzyme 1 Calibrator (ENZ 1 CAL). | 3496 | 2015-05-06 |
| 2010-02-26 | Not classified | Employee error | There is incorrect barcode information, which can potentially cause the Alert Message “Calibrator Insert Missing” to be displayed. | 1310 cartons | 2010-10-13 |
| 2009-10-23 | Not classified | Other | patient results are depressed | 1753 cartons | 2010-06-22 |
| 2009-08-31 | Not classified | Other | Siemens Healthcare Diagnostics, Inc. has confirmed high accuracy shifts with Dimension Vista URCA Flex reagent cartridge (various lots) when calibrating with some vials from CHEM 1 calibrator lot 9DM001. | 1474 Cartons | 2010-12-13 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.