Urine Chemistry Standard Kit
The Urine Chemistry Standard Kit is an in vitro diagnostic calibrator used to calibrate or verify the calibration of clinical chemistry test systems. It provides aqueous primary-standard…
The Urine Chemistry Standard Kit is an in vitro diagnostic calibrator used to calibrate or verify the calibration of clinical chemistry test systems. It provides aqueous primary-standard solutions containing known amounts of the components being measured. It is a laboratory reference material for analytical testing.
Concentrations are assigned by weighing known-purity source materials to establish a weight-per-volume value. The assigned concentrations are checked using available NIST Standard Reference Materials or equivalent primary standards. Reference methods are also used when available.
Lot Information
A certificate of analysis accompanies each kit and identifies the method used to verify the gravimetric concentrations. The materials are lot certified. Their role is to support calibration and calibration verification of the clinical chemistry system.
Who Else Makes It
Concentrated in Jilin (1), Guangdong (1), Jiangsu (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Getein Biotech, Inc. | Nanjing | Jiangsu | Manufacturer | 19 |
Record
| Listed by | Verichem Laboratories, Inc., United States |
|---|---|
| FDA product code | JIX |
| Device type | Calibrator, Multi-Analyte Mixture |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1150 |
| Establishment | Contract manufacturer, Manufacturer |
| 510(k) | K112834 |
| Record published | 2018-01-16 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 9000 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stat Profile | Nova Biomedical Corporation | 54 |
| BioPlex 2200 | Bio-Rad Laboratories Inc. | 32 |
| Plasma Calibrator Set | Chromsystems Instruments & Chemicals Gmbh | 22 |
| Phoenix Diagnostics | Phoenix Diagnostics, Inc. | 20 |
| Nova | Nova Biomedical Corporation | 15 |
| Plasma Calibration Standard | Chromsystems Instruments & Chemicals Gmbh | 15 |
| Phoenix Diagnostics, Inc. | Phoenix Diagnostics, Inc. | 15 |
| Architect | Abbott Laboratories | 11 |
| Alinity | Abbott Medical | 10 |
| Synchron | Beckman Coulter, Inc. | 9 |
| Architect | Abbott Medical | 9 |
| Urine Calibration Standard | Chromsystems Instruments & Chemicals Gmbh | 8 |
Showing 12 of 229. All products under Calibrator, Multi-Analyte Mixture
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K112834 | 2012-03-28 |
| K974290 | 1997-12-19 |
| K973345 | 1997-10-29 |
| K972333 | 1997-07-23 |
| K875285 | 1988-09-02 |
| K882116 | 1988-06-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.