Clinitek Status Connector

The CLINITEK Status Connector is intended for use with the CLINITEK Status+ analyzer.The connector allows network connectivity and centralized control of all the satellite Point of Care…

Registry build 21.09.26

The CLINITEK Status Connector is intended for use with the CLINITEK Status+ analyzer.The connector allows network connectivity and centralized control of all the satellite Point of Care (POC) CLINITEK Status+ analyzerThe connector communicates with remote Hospital and Laboratory Information Systems (HIS/LIS)and interfaces with Electronic Medical Records (EMR).The CLINITEK Status Connector and CLINITEK Status+ analyzer together are the CLINITEK Status Connect system.

12manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Jilin (5), Zhejiang (2), Guangxi (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JJB
Manufacturer City Province Registered as Device types
Zhejiang Orient Gene Biotech Huzhou Zhejiang Contract manufacturer 86
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Urit Medical Electronic Co., Ltd. Guilin Guangxi Contract manufacturer 28
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Changchun Wancheng BIO-Electron Co., Ltd. Changchun Jilin Contract manufacturer 34
Weihai Kangzheng Medical Equipments Technology Co., Ltd. Weihai Shandong Contract manufacturer 26
Changchun Merydi BIO-Tech Co., Ltd. Changchun Jilin Manufacturer 24
Jilin Hongyi BIO-Tech Co., Ltd. Changchun Jilin Manufacturer 24
AVE Science & Technology Co., Ltd. Changsha Hunan Manufacturer 22
Chong Qing Teco Huayi Pharm. Co. Shapingba Dist. Chongqing Contract manufacturer 18
Changchun LYZ Technology Co., Ltd. Changchun Jilin Manufacturer 16
Human Metabolomics Institute, Inc. Shenzhen Guangdong Manufacturer 4

Record

Regulatory record for Clinitek Status Connector
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code JJB
Device type Azo-Dyes, Colorimetric, Bilirubin & Its Conjugates (Urinary, Non-Quant.)
Device class Class 1
Regulation 21 CFR 862.1115
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K091216
Record published 2020-09-30
Record revised 2021-11-19 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Handling environment temperature -20 to 60 °C; Storage environment temperature 5 to 40 °C; Special storage condition: max 95% RH at 45 ‘C

Catalogue Numbers

Catalogue numbers for Clinitek Status Connector
Catalogue number Size Status
11537761 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Mission Urinalysis Reagent Strips Acon Laboratories, Inc. 3
Rapid Response Btnx Inc. 2
Stat Profile Nova Biomedical Corporation 2
Henry Schein Henry Schein, Inc. 1
Ictotest® Reagent Tablets and Mats for Urinalysis Siemens Healthcare Diagnostics Inc 1
Urine Analyzer Urit Medical Electronic Co., Ltd. 1
Cardinal Health Cardinal Health 200, LLC 1
DxU Beckman Coulter, Inc. 1
Diazo-Chek Biorex Labs LLC 1
iChem® Velocity™ Beckman Coulter Ireland Inc 1

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Clinitek Status Connector
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Siemens Healthcare Diagnostics Inc 510(k) number 2013-02-26 Class III Reprocessing Controls Device with Sample Interference Notes (SIN) enabled not cleared for US marketing. 1 unit 2014-05-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer