Chek-Stix® Combo Pak Control+ Control- Strips
Quality control for Siemens urine strips read visually and all analyzers other than Clinitek Atlas® and Clinitek Novus® - 25 positive and 25 negative strips
Who Else Makes It
Concentrated in Jilin (1), Zhejiang (1), Guangxi (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Urit Medical Electronic Co., Ltd. | Guilin | Guangxi | Contract manufacturer | 28 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | JJW |
| Device type | Urinalysis Controls (Assayed And Unassayed) |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1660 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K931467 |
| Record published | 2016-09-24 |
| Record revised | 2021-11-19 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Keep out of direct sunlight; Storage environment temperature 15 to 30 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10310483 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Kova | Kova International Inc | 52 |
| Urine Control | Chromsystems Instruments & Chemicals Gmbh | 16 |
| Urinalysis Controls (Assayed And Unassayed) | Alta Diagnostics, Inc. | 14 |
| Cardinal Health | Cardinal Health 200, LLC | 10 |
| qUAntify | Bio-Rad Laboratories Inc. | 10 |
| McKesson | Mckesson Medical-Surgical Inc. | 7 |
| DxU | Beckman Coulter, Inc. | 6 |
| Cardinal Health | Kova International Inc | 6 |
| MAS UA Control Liquid Assayed Urinalysis Control | Microgenics Corporation | 5 |
| Quality Control Solution For Urine Analyzer | Urit Medical Electronic Co., Ltd. | 4 |
| Urine Control Bi-Level | Chromsystems Instruments & Chemicals Gmbh | 4 |
| Mission Liquid Urine Controls | Acon Laboratories, Inc. | 4 |
Showing 12 of 77. All products under Urinalysis Controls (Assayed And Unassayed)
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-11-21 | Class III | Nonconforming Material/Component | When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). | 6466 | 2014-11-06 |
| 2012-11-21 | Class II | Nonconforming Material/Component | When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). | 1130 | 2014-11-06 |
| 2012-11-21 | Class III | Nonconforming Material/Component | When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). | 700 | 2014-11-06 |
| 2012-11-21 | Class III | Nonconforming Material/Component | When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). | 4642 | 2014-11-06 |
| 2012-11-21 | Class III | Nonconforming Material/Component | When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). | 7865 | 2014-11-06 |
| 2012-11-21 | Class III | Nonconforming Material/Component | When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). | 325 | 2014-11-06 |
| 2012-11-21 | Class III | Nonconforming Material/Component | When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). | 16711 | 2014-11-06 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.