Chek-Stix® Combo Pak Control+ Control- Strips

Quality control for Siemens urine strips read visually and all analyzers other than Clinitek Atlas® and Clinitek Novus® - 25 positive and 25 negative strips

Registry build 21.09.26
3manufacturers in China registered for this device type
1catalogue number
7recalls on this code

Who Else Makes It

Concentrated in Jilin (1), Zhejiang (1), Guangxi (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code JJW
Manufacturer City Province Registered as Device types
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Urit Medical Electronic Co., Ltd. Guilin Guangxi Contract manufacturer 28

Record

Regulatory record for Chek-Stix® Combo Pak Control+ Control- Strips
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code JJW
Device type Urinalysis Controls (Assayed And Unassayed)
Device class Class 1
Regulation 21 CFR 862.1660
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K931467
Record published 2016-09-24
Record revised 2021-11-19 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Label carries lot or batch number, expiry date
Storage Special storage condition: Keep out of direct sunlight; Storage environment temperature 15 to 30 °C

Catalogue Numbers

Catalogue numbers for Chek-Stix® Combo Pak Control+ Control- Strips
Catalogue number Size Status
10310483 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Kova Kova International Inc 52
Urine Control Chromsystems Instruments & Chemicals Gmbh 16
Urinalysis Controls (Assayed And Unassayed) Alta Diagnostics, Inc. 14
Cardinal Health Cardinal Health 200, LLC 10
qUAntify Bio-Rad Laboratories Inc. 10
McKesson Mckesson Medical-Surgical Inc. 7
DxU Beckman Coulter, Inc. 6
Cardinal Health Kova International Inc 6
MAS UA Control Liquid Assayed Urinalysis Control Microgenics Corporation 5
Quality Control Solution For Urine Analyzer Urit Medical Electronic Co., Ltd. 4
Urine Control Bi-Level Chromsystems Instruments & Chemicals Gmbh 4
Mission Liquid Urine Controls Acon Laboratories, Inc. 4

Showing 12 of 77. All products under Urinalysis Controls (Assayed And Unassayed)

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2012-11-21 Class III Nonconforming Material/Component When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). 6466 2014-11-06
2012-11-21 Class II Nonconforming Material/Component When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). 1130 2014-11-06
2012-11-21 Class III Nonconforming Material/Component When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). 700 2014-11-06
2012-11-21 Class III Nonconforming Material/Component When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). 4642 2014-11-06
2012-11-21 Class III Nonconforming Material/Component When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). 7865 2014-11-06
2012-11-21 Class III Nonconforming Material/Component When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). 325 2014-11-06
2012-11-21 Class III Nonconforming Material/Component When these lots of control material are reconstituted, the positive control solution leukocyte result may become negative if the solution is held for more than two hours above 25C (77F). 16711 2014-11-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer