Chromascopics Control Level 1&2 Set 2x25ml (International)

The Chromascopics Urinalysis Control with Microscopics is intended as an assayed quality control for the Siemens Clinitek Novus Automated Urine Chemistry Analyzer. It is also compatible…

Registry build 21.09.26

The Chromascopics Urinalysis Control with Microscopics is intended as an assayed quality control for the Siemens Clinitek Novus Automated Urine Chemistry Analyzer. It is also compatible with Siemens urinalysis dipsticks and Clinitek analyzers, confirmatory tests, and qualitative methods. It may also be used as a means of validating the processing and centrifugation of patient urine samples prior to the microscopic evaluation of urine sediment. It is supplied as a liquid, ready-to-use control in two levels, configured with 2x25mL of each level per bag. It does not required reconstitution or dilution. They are prepared from human urine to which stabilized human red and white blood cells, calcium oxalate crystals, non-pathogenic bacteria, and other compounds have been added to produce desired reactions when tested by the methods indicated in the product insert. Preservatives have been added to inhibit microbial growth.

3manufacturers in China registered for this device type
1catalogue number
2510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Jilin (1), Zhejiang (1), Guangxi (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code JJW
Manufacturer City Province Registered as Device types
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Urit Medical Electronic Co., Ltd. Guilin Guangxi Contract manufacturer 28

Record

Regulatory record for Chromascopics Control Level 1&2 Set 2x25mL (International)
Listed by Quantimetrix Corp., United States
FDA product code JJW
Device type Urinalysis Controls (Assayed And Unassayed)
Device class Class 1
Regulation 21 CFR 862.1660
Establishment Contract manufacturer, Manufacturer, Exporter
Premarket notification Exempt
Record published 2023-05-04

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C; Handling environment temperature 18 to 25 °C

Catalogue Numbers

Catalogue numbers for Chromascopics Control Level 1&2 Set 2x25mL (International)
Catalogue number Size Status
1540-03 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Kova Kova International Inc 52
Urine Control Chromsystems Instruments & Chemicals Gmbh 16
Urinalysis Controls (Assayed And Unassayed) Alta Diagnostics, Inc. 14
Cardinal Health Cardinal Health 200, LLC 10
qUAntify Bio-Rad Laboratories Inc. 10
McKesson Mckesson Medical-Surgical Inc. 7
DxU Beckman Coulter, Inc. 6
Cardinal Health Kova International Inc 6
MAS UA Control Liquid Assayed Urinalysis Control Microgenics Corporation 5
Quality Control Solution For Urine Analyzer Urit Medical Electronic Co., Ltd. 4
Urine Control Bi-Level Chromsystems Instruments & Chemicals Gmbh 4
Mission Liquid Urine Controls Acon Laboratories, Inc. 4

Showing 12 of 77. All products under Urinalysis Controls (Assayed And Unassayed)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K142262 2015-04-10
K831526 1983-08-12

Recalls

1 of these is Class III. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2017-12-21 Class III Mixed-up of materials/components The kits contained an incorrect lot of Dropper Plus Level 1 vials 20 kits 2021-01-27
2007-06-01 Not classified Employee error This recall was initiated due to efficacy concerns with the stabilized erythrocytes, leukocytes and lymphocytes contained in this product group. 24,937 sets for all products. 2009-02-18

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker