IRISpec
Irispec CA/CB/CC Urine Chemistry Controls
3manufacturers in China registered for this device type
2catalogue numbers in this listing
Who Else Makes It
Concentrated in Jilin (1), Zhejiang (1), Guangxi (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Urit Medical Electronic Co., Ltd. | Guilin | Guangxi | Contract manufacturer | 28 |
Record
| Listed by | Beckman Coulter Ireland Inc, Ireland |
|---|---|
| FDA product code | JJW |
| Device type | Urinalysis Controls (Assayed And Unassayed) |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1660 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer |
| 510(k) | K072640 |
| Record published | 2016-09-07 |
| Record revised | 2023-10-13 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| CA/CB/CC URINE CHEMSITRY CONTROLS | In distribution | |
| CA/CB/CC URINE CHEMSITRY CONTROLS | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Kova | Kova International Inc | 52 |
| Urine Control | Chromsystems Instruments & Chemicals Gmbh | 16 |
| Urinalysis Controls (Assayed And Unassayed) | Alta Diagnostics, Inc. | 14 |
| Cardinal Health | Cardinal Health 200, LLC | 10 |
| qUAntify | Bio-Rad Laboratories Inc. | 10 |
| McKesson | Mckesson Medical-Surgical Inc. | 7 |
| DxU | Beckman Coulter, Inc. | 6 |
| Cardinal Health | Kova International Inc | 6 |
| MAS UA Control Liquid Assayed Urinalysis Control | Microgenics Corporation | 5 |
| Quality Control Solution For Urine Analyzer | Urit Medical Electronic Co., Ltd. | 4 |
| Urine Control Bi-Level | Chromsystems Instruments & Chemicals Gmbh | 4 |
| Mission Liquid Urine Controls | Acon Laboratories, Inc. | 4 |
Showing 12 of 77. All products under Urinalysis Controls (Assayed And Unassayed)
Recalls Naming This Product
3 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Beckman Coulter, Inc. | 510(k) number | 2024-07-16 | Class III | Under Investigation by firm | Beckman Coulter has become aware of an increase in customer complaints for intermittent IRISpec CB negative glucose control failure, resulting in false positive control results when used in conjunction with iChemVELOCITY Urine Chemistry Str | 5589 units |
| Beckman Coulter, Inc. | 510(k) number | 2022-11-18 | Class II | Under Investigation by firm | Beckman Coulter has become aware of an increase in customer complaints generated for intermittent IRISpec CB glucose control false positive results when used in conjunction with iChemVelocity Urine Chemistry Strips PN 800-7212 | 3657 units |
| Beckman Coulter, Inc. | UDI-DI | 2022-02-16 | Class III | Under Investigation by firm | IRISpec CA failures for glucose. | 12,306 kits |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.