Advia Centaur® T4 MCM
Advia Centaur T4 Master Curve Material checks calibration and the reportable range of the Advia Centaur thyroxine assay. It is an in vitro diagnostic quality-control material for use on…
Advia Centaur T4 Master Curve Material checks calibration and the reportable range of the Advia Centaur thyroxine assay. It is an in vitro diagnostic quality-control material for use on Advia Centaur systems.
The set contains six levels of levothyroxine in a human-plasma matrix with sodium azide and preservatives. The lyophilized material is reconstituted to 1.0 mL per vial, with the first level containing no analyte.
Listed Item
T4 Master Curve Material Set – CENTAUR – CONS
Assigned Levels
Lot-specific assigned values correspond to target concentrations of 0.00, 2.50, 5.00, 10.0, 15.0 and 35.0 micrograms per decilitre. The material is intended for prescription use.
Who Else Makes It
Concentrated in Zhejiang (3), Guangdong (3), Jilin (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Guangdong Transtek Medical Electronics Co., Ltd. | Zhongshan | Guangdong | Contract manufacturer | 11 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
| BD Rapid Diagnostics (Suzhou) Co., Ltd. | China (Jiangsu) Pilot Free Trade Zone Suzhou Area | Manufacturer | 6 | |
| Sejoy Biomedical Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 5 |
| Beijing Genesee Biotech, Inc. | Beijing | Beijing | Manufacturer | 4 |
| Human Metabolomics Institute, Inc. | Shenzhen | Guangdong | Manufacturer | 4 |
| Changsha Sinocare Inc. | Changsha | Hunan | Manufacturer | 2 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | JJX |
| Device type | Single (Specified) Analyte Controls (Assayed And Unassayed) |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1660 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K143687 |
| Record published | 2020-09-24 |
| Record revised | 2021-11-18 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C; Special storage condition: Store Upright, Protect from Light, Do not freeze, Resuspend. |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10311619 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Vitros | Ortho-Clinical Diagnostics, Inc. | 55 |
| Validate | LGC Clinical Diagnostics, Inc. | 37 |
| Architect | Abbott Laboratories | 24 |
| Architect | Abbott Medical | 23 |
| BioPlex 2200 | Bio-Rad Laboratories Inc. | 22 |
| Architect | Abbott Ireland | 18 |
| Liquichek | Bio-Rad Laboratories Inc. | 17 |
| Alinity | Abbott Medical | 17 |
| Alinity | Abbott Ireland | 15 |
| Fora | Fora Care Inc. | 15 |
| Pregnancy-Skreen | Biochemical Diagnostics, Inc. | 14 |
| Accurun® | LGC Clinical Diagnostics, Inc. | 14 |
Showing 12 of 907. All products under Single (Specified) Analyte Controls (Assayed And Unassayed)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K143687 | 2015-07-17 |
| K150132 | 2015-04-13 |
| K143373 | 2015-02-26 |
| K143636 | 2015-02-25 |
| K143680 | 2015-01-27 |
| K143639 | 2015-01-23 |
| K143504 | 2015-01-14 |
| K143352 | 2014-12-24 |
| K143376 | 2014-12-23 |
| K143194 | 2014-12-05 |
| K142878 | 2014-10-30 |
| K142811 | 2014-10-29 |
| K142864 | 2014-10-29 |
| K141772 | 2014-08-19 |
| K141444 | 2014-07-09 |
| K133816 | 2014-06-24 |
| K140818 | 2014-05-01 |
| K140541 | 2014-04-01 |
| K140505 | 2014-03-31 |
| K140267 | 2014-03-10 |
| K140258 | 2014-03-05 |
| K132739 | 2014-01-14 |
| K133122 | 2013-10-30 |
| K133124 | 2013-10-25 |
| K133128 | 2013-10-22 |
| K131662 | 2013-10-10 |
| K131536 | 2013-08-12 |
| K122534 | 2013-03-14 |
| K121084 | 2012-05-09 |
| K110061 | 2011-09-21 |
| K103683 | 2011-04-28 |
| K102904 | 2010-11-23 |
| K092993 | 2009-11-20 |
| K091123 | 2009-08-14 |
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2023-01-09 | Class II | Under Investigation by firm | Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. | 124 kits | |
| 2023-01-09 | Class II | Under Investigation by firm | Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. | 7,884 kits | |
| 2023-01-09 | Class II | Under Investigation by firm | Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. | 14,669 kits | |
| 2017-01-10 | Class II | Unknown/Undetermined by firm | Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn | 194 kits | 2019-07-16 |
| 2017-01-10 | Class II | Unknown/Undetermined by firm | Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn | 1937 kits | 2019-07-16 |
| 2017-01-10 | Class II | Unknown/Undetermined by firm | Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn | 9664 kits | 2019-07-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.