Advia Centaur® Testosterone 2 MCM

Testosterone 2 Master Curve Material SET - CENTAUR - CONS

Registry build 21.09.26
12manufacturers in China registered for this device type
1catalogue number
34510(k) clearances naming this product code
6recalls on this code

Who Else Makes It

Concentrated in Zhejiang (3), Guangdong (3), Jilin (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JJX
Manufacturer City Province Registered as Device types
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Flextronics Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 5
Yasee Biomedical Inc Qingdao Shandong Contract manufacturer 5
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Vivachek Biotech (Hangzhou) Co., Ltd. Hangzhou, Zhuji Zhejiang Contract manufacturer 21
Guangdong Transtek Medical Electronics Co., Ltd. Zhongshan Guangdong Contract manufacturer 11
Tianjin Empecs Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 8
BD Rapid Diagnostics (Suzhou) Co., Ltd. China (Jiangsu) Pilot Free Trade Zone Suzhou Area Manufacturer 6
Sejoy Biomedical Co., Ltd. Hangzhou Zhejiang Manufacturer 5
Beijing Genesee Biotech, Inc. Beijing Beijing Manufacturer 4
Human Metabolomics Institute, Inc. Shenzhen Guangdong Manufacturer 4
Changsha Sinocare Inc. Changsha Hunan Manufacturer 2

Record

Regulatory record for Advia Centaur® Testosterone 2 MCM
Listed by Siemens Healthcare Diagnostics Inc, United States
FDA product code JJX
Device type Single (Specified) Analyte Controls (Assayed And Unassayed)
Device class Class 1
Regulation 21 CFR 862.1660
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2020-09-24
Record revised 2023-07-07 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Advia Centaur® Testosterone 2 MCM
Catalogue number Size Status
10492623 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Vitros Ortho-Clinical Diagnostics, Inc. 55
Validate LGC Clinical Diagnostics, Inc. 37
Architect Abbott Laboratories 24
Architect Abbott Medical 23
BioPlex 2200 Bio-Rad Laboratories Inc. 22
Architect Abbott Ireland 18
Liquichek Bio-Rad Laboratories Inc. 17
Alinity Abbott Medical 17
Alinity Abbott Ireland 15
Fora Fora Care Inc. 15
Pregnancy-Skreen Biochemical Diagnostics, Inc. 14
Accurun® LGC Clinical Diagnostics, Inc. 14

Showing 12 of 907. All products under Single (Specified) Analyte Controls (Assayed And Unassayed)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K143687 2015-07-17
K150132 2015-04-13
K143373 2015-02-26
K143636 2015-02-25
K143680 2015-01-27
K143639 2015-01-23
K143504 2015-01-14
K143352 2014-12-24
K143376 2014-12-23
K143194 2014-12-05
K142878 2014-10-30
K142811 2014-10-29
K142864 2014-10-29
K141772 2014-08-19
K141444 2014-07-09
K133816 2014-06-24
K140818 2014-05-01
K140541 2014-04-01
K140505 2014-03-31
K140267 2014-03-10
K140258 2014-03-05
K132739 2014-01-14
K133122 2013-10-30
K133124 2013-10-25
K133128 2013-10-22
K131662 2013-10-10
K131536 2013-08-12
K122534 2013-03-14
K121084 2012-05-09
K110061 2011-09-21
K103683 2011-04-28
K102904 2010-11-23
K092993 2009-11-20
K091123 2009-08-14

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2023-01-09 Class II Under Investigation by firm Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. 124 kits
2023-01-09 Class II Under Investigation by firm Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. 7,884 kits
2023-01-09 Class II Under Investigation by firm Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. 14,669 kits
2017-01-10 Class II Unknown/Undetermined by firm Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn 194 kits 2019-07-16
2017-01-10 Class II Unknown/Undetermined by firm Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn 1937 kits 2019-07-16
2017-01-10 Class II Unknown/Undetermined by firm Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn 9664 kits 2019-07-16

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for