Atellica IM AB12 QC
Active-B12 (AB12) QC Kit Atellica IM - CLT 2 x 1 x 7.0mL
Who Else Makes It
Concentrated in Zhejiang (3), Guangdong (3), Jilin (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Guangdong Transtek Medical Electronics Co., Ltd. | Zhongshan | Guangdong | Contract manufacturer | 11 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
| BD Rapid Diagnostics (Suzhou) Co., Ltd. | China (Jiangsu) Pilot Free Trade Zone Suzhou Area | Manufacturer | 6 | |
| Sejoy Biomedical Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 5 |
| Beijing Genesee Biotech, Inc. | Beijing | Beijing | Manufacturer | 4 |
| Human Metabolomics Institute, Inc. | Shenzhen | Guangdong | Manufacturer | 4 |
| Changsha Sinocare Inc. | Changsha | Hunan | Manufacturer | 2 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | JJX |
| Device type | Single (Specified) Analyte Controls (Assayed And Unassayed) |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1660 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K160757 |
| Record published | 2018-10-19 |
| Record revised | 2021-11-18 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 10733002 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Vitros | Ortho-Clinical Diagnostics, Inc. | 55 |
| Validate | LGC Clinical Diagnostics, Inc. | 37 |
| Architect | Abbott Laboratories | 24 |
| Architect | Abbott Medical | 23 |
| BioPlex 2200 | Bio-Rad Laboratories Inc. | 22 |
| Architect | Abbott Ireland | 18 |
| Liquichek | Bio-Rad Laboratories Inc. | 17 |
| Alinity | Abbott Medical | 17 |
| Alinity | Abbott Ireland | 15 |
| Fora | Fora Care Inc. | 15 |
| Pregnancy-Skreen | Biochemical Diagnostics, Inc. | 14 |
| Accurun® | LGC Clinical Diagnostics, Inc. | 14 |
Showing 12 of 907. All products under Single (Specified) Analyte Controls (Assayed And Unassayed)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K143687 | 2015-07-17 |
| K150132 | 2015-04-13 |
| K143373 | 2015-02-26 |
| K143636 | 2015-02-25 |
| K143680 | 2015-01-27 |
| K143639 | 2015-01-23 |
| K143504 | 2015-01-14 |
| K143352 | 2014-12-24 |
| K143376 | 2014-12-23 |
| K143194 | 2014-12-05 |
| K142878 | 2014-10-30 |
| K142811 | 2014-10-29 |
| K142864 | 2014-10-29 |
| K141772 | 2014-08-19 |
| K141444 | 2014-07-09 |
| K133816 | 2014-06-24 |
| K140818 | 2014-05-01 |
| K140541 | 2014-04-01 |
| K140505 | 2014-03-31 |
| K140267 | 2014-03-10 |
| K140258 | 2014-03-05 |
| K132739 | 2014-01-14 |
| K133122 | 2013-10-30 |
| K133124 | 2013-10-25 |
| K133128 | 2013-10-22 |
| K131662 | 2013-10-10 |
| K131536 | 2013-08-12 |
| K122534 | 2013-03-14 |
| K121084 | 2012-05-09 |
| K110061 | 2011-09-21 |
| K103683 | 2011-04-28 |
| K102904 | 2010-11-23 |
| K092993 | 2009-11-20 |
| K091123 | 2009-08-14 |
Recalls
6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2023-01-09 | Class II | Under Investigation by firm | Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. | 124 kits | |
| 2023-01-09 | Class II | Under Investigation by firm | Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. | 7,884 kits | |
| 2023-01-09 | Class II | Under Investigation by firm | Negative bias occurred when whole blood calibration (Atellica IM Fol or ADVIA Centaur FolateBA/FolBA) used to test serum samples. | 14,669 kits | |
| 2017-01-10 | Class II | Unknown/Undetermined by firm | Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn | 194 kits | 2019-07-16 |
| 2017-01-10 | Class II | Unknown/Undetermined by firm | Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn | 1937 kits | 2019-07-16 |
| 2017-01-10 | Class II | Unknown/Undetermined by firm | Siemens Healthcare Diagnostics has confirmed a negative bias for ADVIA Centaur FT4 when used with Calibrator A kit lots ending in 90 on the ADVIA Centaur, ADVIA Centaur XP and ADVIA Centaur XPT Systems. In addition, Siemens Healthcare Diagn | 9664 kits | 2019-07-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.