IDS High Sensitive Estradiol Control Set
For In Vitro Diagnostic Use. For Laboratory Professional Use. The IDS High Sensitive Estradiol Control Set is for in vitro diagnostic use, for the quality control of the IDS High Sensitive…
For In Vitro Diagnostic Use. For Laboratory Professional Use. The IDS High Sensitive Estradiol Control Set is for in vitro diagnostic use, for the quality control of the IDS High Sensitive Estradiol on the IDS system.
Who Else Makes It
Concentrated in Zhejiang (3), Guangdong (3), Jilin (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Acon Biotech (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 29 |
| Flextronics Industrial (Shenzhen) Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Yasee Biomedical Inc | Qingdao | Shandong | Contract manufacturer | 5 |
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| Vivachek Biotech (Hangzhou) Co., Ltd. | Hangzhou, Zhuji | Zhejiang | Contract manufacturer | 21 |
| Guangdong Transtek Medical Electronics Co., Ltd. | Zhongshan | Guangdong | Contract manufacturer | 11 |
| Tianjin Empecs Medical Device Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 8 |
| BD Rapid Diagnostics (Suzhou) Co., Ltd. | China (Jiangsu) Pilot Free Trade Zone Suzhou Area | Manufacturer | 6 | |
| Sejoy Biomedical Co., Ltd. | Hangzhou | Zhejiang | Manufacturer | 5 |
| Beijing Genesee Biotech, Inc. | Beijing | Beijing | Manufacturer | 4 |
| Human Metabolomics Institute, Inc. | Shenzhen | Guangdong | Manufacturer | 4 |
| Changsha Sinocare Inc. | Changsha | Hunan | Manufacturer | 2 |
Record
| Listed by | Immunodiagnostic Systems Ltd., United Kingdom |
|---|---|
| FDA product code | JJX |
| Device type | Single (Specified) Analyte Controls (Assayed And Unassayed) |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1660 |
| Establishment | Contract manufacturer, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2026-06-24 |
Specifications
| MRI safety | MR Safe |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| IS-5230HS | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Vitros | Ortho-Clinical Diagnostics, Inc. | 55 |
| Validate | LGC Clinical Diagnostics, Inc. | 37 |
| Architect | Abbott Laboratories | 24 |
| Architect | Abbott Medical | 23 |
| BioPlex 2200 | Bio-Rad Laboratories Inc. | 22 |
| Architect | Abbott Ireland | 18 |
| Liquichek | Bio-Rad Laboratories Inc. | 17 |
| Alinity | Abbott Medical | 17 |
| Alinity | Abbott Ireland | 15 |
| Fora | Fora Care Inc. | 15 |
| Pregnancy-Skreen | Biochemical Diagnostics, Inc. | 14 |
| Accurun® | LGC Clinical Diagnostics, Inc. | 14 |
Showing 12 of 907. All products under Single (Specified) Analyte Controls (Assayed And Unassayed)
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K161082 | 2016-05-17 |
| K143324 | 2015-03-30 |
| K122141 | 2012-08-07 |
| K111938 | 2012-02-14 |
| K111650 | 2011-09-06 |
| K110412 | 2011-03-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.