Vigil

Vigil HbA1c Controls Levels 1 & 2

Registry build 21.09.26
12manufacturers in China registered for this device type
1catalogue number
9510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Zhejiang (3), Guangdong (3), Jilin (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JJX
Manufacturer City Province Registered as Device types
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Flextronics Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 5
Yasee Biomedical Inc Qingdao Shandong Contract manufacturer 5
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Vivachek Biotech (Hangzhou) Co., Ltd. Hangzhou, Zhuji Zhejiang Contract manufacturer 21
Guangdong Transtek Medical Electronics Co., Ltd. Zhongshan Guangdong Contract manufacturer 11
Tianjin Empecs Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 8
BD Rapid Diagnostics (Suzhou) Co., Ltd. China (Jiangsu) Pilot Free Trade Zone Suzhou Area Manufacturer 6
Sejoy Biomedical Co., Ltd. Hangzhou Zhejiang Manufacturer 5
Beijing Genesee Biotech, Inc. Beijing Beijing Manufacturer 4
Human Metabolomics Institute, Inc. Shenzhen Guangdong Manufacturer 4
Changsha Sinocare Inc. Changsha Hunan Manufacturer 2

Record

Regulatory record for Vigil
Listed by Beckman Coulter, Inc., United States
FDA product code JJX
Device type Single (Specified) Analyte Controls (Assayed And Unassayed)
Device class Class 1
Regulation 21 CFR 862.1660
Establishment Contract manufacturer, Specification developer, Manufacturer, Exporter
510(k) K982022
Record published 2016-08-24
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Vigil
Catalogue number Size Status
650038 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Vitros Ortho-Clinical Diagnostics, Inc. 55
Validate LGC Clinical Diagnostics, Inc. 37
Architect Abbott Laboratories 24
Architect Abbott Medical 23
BioPlex 2200 Bio-Rad Laboratories Inc. 22
Architect Abbott Ireland 18
Liquichek Bio-Rad Laboratories Inc. 17
Alinity Abbott Medical 17
Alinity Abbott Ireland 15
Fora Fora Care Inc. 15
Pregnancy-Skreen Biochemical Diagnostics, Inc. 14
Accurun® LGC Clinical Diagnostics, Inc. 14

Showing 12 of 907. All products under Single (Specified) Analyte Controls (Assayed And Unassayed)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K112603 2011-11-04
K010693 2001-04-11
K010428 2001-03-13
K001458 2000-06-02
K994200 2000-01-18
K994277 2000-01-14
K993210 2000-01-05
K982022 1998-07-06
K981864 1998-06-12

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-10-24 Class II Under Investigation by firm Beckman Coulter has determined that the Access Ostase Calibrator and Access Ostase QC lots do not meet their expiration date claims within the 10% criteria. 625 kits total (113 kits in US) 2018-02-01
2011-11-10 Not classified Process design The recall was initiated because Beckman confirmed that the Access Ostase Calibrator and QC lots do not meet expiration date claims. The Access Ostase Reagent Kit lots identified were quality control tested and released using Access Ostase 4961 units total (1321 units in US) 2012-06-26
2011-05-10 Not classified Package design/selection The recall was initiated because Beckman Coulter has confirmed that Access Ostase Calibrator and QC vials from the affected lots have shown an increased rate of fracturing and may leak the contents in the box during shipment to customers.
O
702 kits 2012-07-11
2010-04-21 Not classified Other The recall was initiated after Beckman Coulter confirmed an issue with the Access AFP QC kits (REF 33219) which contain three levels of control material identified as QC1, QC2, and QC3, Beckman Coulter has confirmed that vials of QC1 in the 166 2012-05-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer