Safe-T-Fill®
SAFE-T-FILL® Micro Capillary Blood Collection, 200 µL; Prepared with Clot Activator and Serum Separator Gel; Amber Microtube, Red
Who Else Makes It
Concentrated in Jiangsu (7), Zhejiang (6), Shanghai (3). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Promisemed Hangzhou Meditech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 21 |
| Beilun Plastech Inc | Ningbo | Zhejiang | Contract manufacturer | 13 |
| Weihai Jierui Medical Products Co., Ltd. | Weihai | Shandong | Contract manufacturer | 3 |
| Tianjin Hanaco Medical Co., Ltd. | Tianjin | Tianjin | Contract manufacturer | 3 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Zhejiang Medicines & Health Products I/ E Co., Ltd. | Hangzhou | Zhejiang | Exporter | 41 |
| Jiangsu Caina Medical Co., Ltd. | Jiangyin | Jiangsu | Contract manufacturer | 20 |
| Hangzhou Best Valley Medical Technology Co., Ltd. | Hangzhou | Zhejiang | Exporter | 20 |
| Zhejiang Kindly Medical Devices Co., Ltd. | Wenzhou | Zhejiang | Contract manufacturer | 16 |
| Jiangsu Rongye Technology Co., Ltd. | Yangzhou | Jiangsu | Manufacturer | 16 |
| Yangzhou Medline Industry Co., Ltd. | Yangzhou | Jiangsu | Contract manufacturer | 11 |
| Shanghai Mekon Medical Devices Co., Ltd. | Shanghai | Shanghai | Exporter | 11 |
Showing 12 of 23. All 23 manufacturers in China registered for Tubes, Vials, Systems, Serum Separators, Blood Collection
Record
| Listed by | Ram Scientific, United States |
|---|---|
| FDA product code | JKA |
| Device type | Tubes, Vials, Systems, Serum Separators, Blood Collection |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1675 |
| Record published | 2016-09-15 |
| Record revised | 2025-12-23 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Keep Dry.; Special storage condition: Keep away from sunlight. |
| Packaging | Case of 10, carton of 80, carton of 60, carton of 100, case of 20, carton of 160 |
| Sizes | Total volume 125 to 300 Microliter; total volume 1 ml |
| Distribution end date | 2025-05-16 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 07 6014 | Total Volume 150 Microliter | Withdrawn | |
| 07 7340 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 6013 | Total Volume 125 Microliter | 50 | Withdrawn |
| 07 7250 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 7151 | Total Volume 300 Microliter | 50 | Withdrawn |
| 07 7120 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 7421 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 7121 | Total Volume 300 Microliter | 50 | Withdrawn |
| 07 8021 | Total Volume 1 ml | 50 | Withdrawn |
| 07 7220 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 7150 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 6011 | Total Volume 125 Microliter | 50 | Withdrawn |
| 07 8052 | Total Volume 1 ml | 50 | Withdrawn |
| 07 7251 | Total Volume 300 Microliter | 50 | Withdrawn |
| 07 7450 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 6101 | Total Volume 125 Microliter | 50 | Withdrawn |
| 07 7056 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 7455 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 7221 | Total Volume 300 Microliter | 50 | Withdrawn |
| 07 7053 | Total Volume 300 Microliter | 50 | Withdrawn |
| 07 7052 | Total Volume 150 Microliter | 50 | Withdrawn |
| 07 7058 | Total Volume 200 Microliter | 50 | Withdrawn |
| 07 7051 | Total Volume 200 Microliter | 50 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Portex | ICU Medical, Inc | 182 |
| S-Monovette® | Sarstedt Aktiengesellschaft & Co.KG | 108 |
| Vacuette | Greiner BIO-ONE Gmbh | 106 |
| Jelco | ICU Medical, Inc | 35 |
| Kbmed | KB Medical (Group) Inc. | 33 |
| Marketlab Inc | Marketlab Incorporated | 30 |
| Maveric Medical | Maveric Medical LLC | 27 |
| Improvacuter® Gel & Clot Activator Tube | Guangzhou Improve Medical Instruments Co., Ltd. | 21 |
| Medline | Medline Industries, Inc. | 20 |
| Kurin Blood Culture Collection Set | Kurin, Inc. | 20 |
| Reli | Myco Medical Supplies, Inc. | 18 |
| icu medical | Jiangsu Caina Medical Co., Ltd. | 18 |
Showing 12 of 303. All products under Tubes, Vials, Systems, Serum Separators, Blood Collection
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K983517 | 1998-11-12 |
| K981973 | 1998-09-03 |
Recalls Naming This Product
11 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 78000 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 50050 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 64850 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 27950 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 6600 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 49000 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 9150 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 103200 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 6050 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 2100 |
| ASP Global, LLC | UDI-DI | 2025-09-26 | Class II | Process change control | Due to products manufactured under an inadequate quality system to include unvalidated manufacturing processes. | 1500 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.