Vitros

VITROS Immunodiagnostic Products TSH Reagent Pack

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
2510(k) clearances naming this product code
4recalls on this code

Who Else Makes It

Concentrated in Zhejiang (1), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code JLW
Manufacturer City Province Registered as Device types
Hangzhou AllTest Biotech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 48
Roche Diagnostics (Suzhou) Ltd. Suzhou Jiangsu Manufacturer 3

Record

Regulatory record for Vitros
Listed by Ortho-Clinical Diagnostics, Inc., United States
FDA product code JLW
Device type Radioimmunoassay, Thyroid-Stimulating Hormone
Device class Class 2
Regulation 21 CFR 862.1690
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2016-08-26
Record revised 2025-02-19 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: Do not freeze; Storage environment temperature 2 to 8 °C
Packaging Case of 30

Catalogue Numbers

Catalogue numbers for Vitros
Catalogue number Size Status
1912997 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Atellica IM TSH3-UL Siemens Healthcare Diagnostics Inc 4
Elecsys TSH Roche Diagnostics Gmbh 4
Advia Centaur® TSH3-UL Siemens Healthcare Diagnostics Inc 3
Advia Centaur® TSH Siemens Healthcare Diagnostics Inc 3
Atellica IM TSH3-Ultra II Siemens Healthcare Diagnostics Inc 3
Free T3, Free T4, TSH Thyroid Panel AccuBind Vast Elisa Test System – 960 Wells Monobind, Inc. 3
Architect Abbott Ireland 2
Immulite 2000 Third Generation TSH Siemens Healthcare Diagnostics Products GmbH 2
Thyrotropin (TSH) Elisa DRG Instruments Gesellschaft mit beschränkter Haftung 2
AccuDiag ™ Diagnostic Automation, Inc. 2
Immulite® 2000 Systems TSH Third Generation TSH Siemens Healthcare Diagnostics Products GmbH 2
Maglumi 2000 TSH Shenzhen NEW Industries Biomedical Engineering Co., Ltd. 2

Showing 12 of 87. All products under Radioimmunoassay, Thyroid-Stimulating Hormone

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K083173 2008-12-22
K081543 2008-10-23

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-08-15 Class II Software design Potential for the VITROS 5600 Integrated System to dispense an insufficient sample volume onto a MicroSlide without suppressing the potentially incorrect result. U.S.= 66 ex-U.S.= 76 2022-01-10
2018-08-15 Class II Software design Potential for the VITROS 5600 Integrated System to dispense an insufficient sample volume onto a MicroSlide without suppressing the potentially incorrect result. U.S.= 1255 ex-U.S.= 1504 2022-01-10
2018-07-12 Class II Device Design The recalling firm determined that biased results may occur for specific VITROS Immunodiagnostic Products (MicroWell Assays) at biotin concentrations which are lower than indicated in the current Instructions For Use (IFU). Patients who are 68230
2016-07-28 Class III Under Investigation by firm A field correction was issued by the firm for VITROS TSH reagent lot 5040 due to a higher than expected frequency of customer calibration curves falling outside of the calibration quality parameters and therefore unusable to process samples Domestic: 2883, Foreign: 1261 2018-06-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer