Pointe Scientific, Inc.

HDL Cholesterol Standard, for use as a cholesterol standard for standardization or calibration of enzymatic, endpoint cholesterol assays used with HDL Cholesterol procedures. Size: 1 x 15…

Registry build 21.09.26

HDL Cholesterol Standard, for use as a cholesterol standard for standardization or calibration of enzymatic, endpoint cholesterol assays used with HDL Cholesterol procedures. Size: 1 x 15 mL. Concentration: 50 mg/dL

3manufacturers in China registered for this device type
11catalogue numbers in this listing
6recalls on this code

Who Else Makes It

Concentrated in Zhejiang (2), Guangxi (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code LBR
Manufacturer City Province Registered as Device types
Acon Biotech (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 29
Urit Medical Electronic Co., Ltd. Guilin Guangxi Contract manufacturer 28
Hangzhou Lysun Biotechnology Co., Ltd. Hangzhou Zhejiang Manufacturer 22

Record

Regulatory record for Pointe Scientific, Inc.
Listed by Horiba Instruments Incorporated, United States
FDA product code LBR
Device type Ldl & Vldl Precipitation, Hdl
Device class Class 1
Regulation 21 CFR 862.1475
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K891117
Record published 2016-08-31
Record revised 2025-10-02 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for Pointe Scientific, Inc.
Catalogue number Size Status
H7507-80 In distribution
13-H7511-30 In distribution
H7545-1000 In distribution
H7511-60 In distribution
H7545-320 In distribution
H7545-CAL In distribution
H7545-40 In distribution
H7512-STD In distribution
H7545-80 In distribution
13-H7512-STD In distribution
HH945-240 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Synermed® Infrared Laboratory Systems LLC 4
LDL-Cholesterol Gen.3 Roche Diagnostics Gmbh 3
L-Type HDL-C Reagent 2 Fujifilm Wako Pure Chemical Corporation 2
Teco Diagnostics Direct HDL Cholesterol Reagent Kit TC-Matrix Teco Diagnostics 2
N-geneous LDL Cholesterol Reagent (R1) Sekisui Diagnostics, LLC 2
N-geneous LDL Cholesterol Reagent (R2) Sekisui Diagnostics, LLC 2
PTS Panels® HDL Cholesterol Test Strips Polymer Technology Systems 2
Teco Diagnostics HDL Cholesterol Reagent Set Teco Diagnostics 2
CardioChek Henry Schein, Inc. 2
L-Type HDL-C Reagent 1 Fujifilm Wako Pure Chemical Corporation 2
Carolina Liquid Chemistries Corp.® CLC720 HDL RGT KIT Product No. ST616 Carolina Liquid Chemistries 1
Curo L5 KPI Healthcare, Inc. 1

Showing 12 of 47. All products under Ldl & Vldl Precipitation, Hdl

Recalls Naming This Product

9 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Pointe Scientific, Inc.
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Horiba Instruments Incorporated 510(k) number 2018-08-10 Class III Error in labeling Vials of the autoHDL/LDL Calibrator were shipped without a vial label. 22 2019-12-04
Horiba Instruments Incorporated 510(k) number 2015-03-13 Class III Nonconforming Material/Component Crystals may be observed in the R1 reagent. Crystals may be a result of the reagent being frozen during transport. The crystals do not impact product performance. H7545-R1, 8.75 L; 12-H7545-162, 4 kits; H7545-1000, 3 kits; 2015-10-29
Horiba Instruments Incorporated 510(k) number 2009-11-10 Not classified Process control The firm initiated the recall due to the presence of visible contamination of the product. 379 sets 2011-02-11
Horiba Instruments Incorporated 510(k) number 2009-11-10 Not classified Process control The firm initiated the recall due to the presence of visible contamination of the product. 237 sets plus 9L 2011-02-11
Horiba Instruments Incorporated 510(k) number 2009-01-29 Not classified Nonconforming Material/Component The R1 reagent has microbial contamination. 497 kits, 93L 2010-10-20
Horiba Instruments Incorporated 510(k) number 2009-01-29 Not classified Nonconforming Material/Component The R1 reagent has microbial contamination. 717 kits, 164L 2010-10-20
Stanbio Laboratory 510(k) number 2006-09-18 Not classified Other Unexpected changes in QC and proficiency results due to QC and proficiency material matrix. 47 test kits. 2007-06-06
Stanbio Laboratory 510(k) number 2006-09-18 Not classified Other Unexpected changes in QC and proficiency results due to QC and proficiency material matrix. 05276CE: 78 test kits; 05312CE: 6 test kits; 05299CE: 10 tes 2007-06-06
Stanbio Laboratory 510(k) number 2006-09-18 Not classified Other Unexpected changes in QC and proficiency results due to QC and proficiency material matrix. 9 test kits. 2007-06-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer