Atellica CH Hdlc
HDL Cholesterol (HDLC) Atellica CH Assay 1792 Tests
Who Else Makes It
Concentrated in Guangdong (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Shijiazhuang Hipro Biotechnology Co., Ltd. | Shijiazhuang | Hebei | Manufacturer | 22 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | LBS |
| Device type | Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1475 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2022-07-08 |
| Record revised | 2023-07-06 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C; Special storage condition: Protect from light, do not freeze; Handling environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 11537213 | 4 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| JAS Diagnostics | Drew Scientific, Ltd. | 6 |
| Direct HDL-Cholesterol (HDL) | Randox Laboratories Limited | 4 |
| Synermed® | Infrared Laboratory Systems LLC | 4 |
| AU | Beckman Coulter, Inc. | 4 |
| HDL-Cholesterol Gen.4 | Roche Diagnostics Gmbh | 4 |
| Direct HDL Cholesterol LiquiColor® | Stanbio Laboratory, L.P. | 3 |
| Ultra N-geneous HDL Cholesterol Reagent | Sekisui Diagnostics, LLC | 2 |
| Advia® Chemistry D-HDL Direct HDL Cholesterol Reagents | Siemens Healthcare Diagnostics Inc | 2 |
| Vitros | Ortho-Clinical Diagnostics, Inc. | 2 |
| Alinity | Abbott Medical | 2 |
| ox-LDL Elisa | Immundiagnostik, Inc. | 2 |
| ACE | Alfa Wassermann | 2 |
Showing 12 of 30. All products under Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Siemens Healthcare Diagnostics Inc | UDI-DI | 2023-07-10 | Class II | Under Investigation by firm | Potential for reagent carryover on the Atellica CH 930 resulting in a positive bias that could impact quality control (QC), patient samples, and calibrator results with from Atellica CH Total Bilirubin_2 (TBil_2), Atellica CH LDL Choleste | 18524 units |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-03-17 | Class II | Device Design | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn | 137422 units total | 2017-09-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.