HDL-Cholesterol Plus 3rd Generation
Catalogue number 05401488190, listed by Roche Diagnostics Gmbh, Germany, under Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl. 2 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Guangdong (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Shijiazhuang Hipro Biotechnology Co., Ltd. | Shijiazhuang | Hebei | Manufacturer | 22 |
Record
| Listed by | Roche Diagnostics Gmbh, Germany |
|---|---|
| FDA product code | LBS |
| Device type | Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1475 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K963213 |
| Record published | 2021-02-08 |
| Record revised | 2023-07-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 05401488190 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| JAS Diagnostics | Drew Scientific, Ltd. | 6 |
| Direct HDL-Cholesterol (HDL) | Randox Laboratories Limited | 4 |
| Synermed® | Infrared Laboratory Systems LLC | 4 |
| AU | Beckman Coulter, Inc. | 4 |
| HDL-Cholesterol Gen.4 | Roche Diagnostics Gmbh | 4 |
| Direct HDL Cholesterol LiquiColor® | Stanbio Laboratory, L.P. | 3 |
| Ultra N-geneous HDL Cholesterol Reagent | Sekisui Diagnostics, LLC | 2 |
| Advia® Chemistry D-HDL Direct HDL Cholesterol Reagents | Siemens Healthcare Diagnostics Inc | 2 |
| Vitros | Ortho-Clinical Diagnostics, Inc. | 2 |
| Alinity | Abbott Medical | 2 |
| ox-LDL Elisa | Immundiagnostik, Inc. | 2 |
| ACE | Alfa Wassermann | 2 |
Showing 12 of 30. All products under Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K033610 | 2003-12-05 |
| K012286 | 2001-08-08 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Roche Diagnostics Operations | 510(k) number | 2015-05-07 | Class II | Under Investigation by firm | Possible drug interference when using the Trinder reaction method on multiple Cobas Analyzers. Results of Trinder tests may be falsely decreased when the tests are run with urine samples (Creatinine plus and Uric Acid applications only) or | 6255 analytical units | 2017-03-24 |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2008-06-11 | Not classified | Labeling Change Control | Some of the labels are glossy, resulting in the bar code being difficult to read by the bar code reader. | 1245 | 2009-09-22 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.