HDL
An HDL-cholesterol test system is a device intended for the quantitative in vitro determination of HDL-cholesterol concentration in human serum and plasma.
Who Else Makes It
Concentrated in Guangdong (1), Hebei (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dongguan BAO Kang Dian ZI KE JI Limited | Dongguan | Guangdong | Contract manufacturer | 24 |
| Shijiazhuang Hipro Biotechnology Co., Ltd. | Shijiazhuang | Hebei | Manufacturer | 22 |
Record
| Listed by | Randox Laboratories Limited, United Kingdom |
|---|---|
| FDA product code | LBS |
| Device type | Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl |
| Device class | Class 1 |
| Regulation | 21 CFR 862.1475 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K982341 |
| Record published | 2018-12-24 |
| Record revised | 2023-07-06 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Store protected from light; Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| CH3811 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| JAS Diagnostics | Drew Scientific, Ltd. | 6 |
| Direct HDL-Cholesterol (HDL) | Randox Laboratories Limited | 4 |
| Synermed® | Infrared Laboratory Systems LLC | 4 |
| AU | Beckman Coulter, Inc. | 4 |
| HDL-Cholesterol Gen.4 | Roche Diagnostics Gmbh | 4 |
| Direct HDL Cholesterol LiquiColor® | Stanbio Laboratory, L.P. | 3 |
| Ultra N-geneous HDL Cholesterol Reagent | Sekisui Diagnostics, LLC | 2 |
| Advia® Chemistry D-HDL Direct HDL Cholesterol Reagents | Siemens Healthcare Diagnostics Inc | 2 |
| Vitros | Ortho-Clinical Diagnostics, Inc. | 2 |
| Alinity | Abbott Medical | 2 |
| ox-LDL Elisa | Immundiagnostik, Inc. | 2 |
| ACE | Alfa Wassermann | 2 |
Showing 12 of 30. All products under Ldl & Vldl Precipitation, Cholesterol Via Esterase-Oxidase, Hdl
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K153435 | 2016-01-08 |
| K982341 | 1998-07-30 |
| K970735 | 1997-06-06 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Siemens Healthcare Diagnostics Inc | 510(k) number | 2016-03-17 | Class II | Device Design | Siemens Healthcare Diagnostics has become aware of N-Acetylcysteine (NAC) and Metamizole (Dipyrone) interference with Trinder and Trinder-like reaction assays. Siemens has confirmed that falsely depressed results may occur on samples drawn | 137422 units total | 2017-09-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.