OneTouch Verio

OneTouch Verio Blood Glucose Test Strips. In vitro Diagnostic. For Self-testing. For blood glucose testing with the OneTouch Verio Family of Meters.For DME Beneficiaries Only

Registry build 21.09.26
5manufacturers in China registered for this device type
8catalogue numbers in this listing

Who Else Makes It

Concentrated in Tianjin (2), Guangdong (2), Jiangsu (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LFR
Manufacturer City Province Registered as Device types
Andon Health Co., Ltd. Tianjin Tianjin Contract manufacturer 22
Flextronics Medical Device Manufacturing (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 6
Flextronics Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 5
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Tianjin Empecs Medical Device Co., Ltd. Tianjin Tianjin Contract manufacturer 8

Record

Regulatory record for OneTouch Verio
Listed by Lifescan Europe Gmbh, Switzerland
FDA product code LFR
Device type Glucose Dehydrogenase, Glucose
Device class Class 2
Regulation 21 CFR 862.1345
Establishment Specification developer, Manufacturer
510(k) K131363
Record published 2020-04-12
Record revised 2026-04-13 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Over the counter Yes
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Storage environment temperature 41 to 86 °F; Special storage condition: Discard 6 months after opening; Special storage condition: Store your test strips in the vial only
Packaging Shipper case of 450, shipper case of 24, shipper case of 240, shipper case of 32
Distribution end date 2025-12-04

Catalogue Numbers

Catalogue numbers for OneTouch Verio
Catalogue number Size Per pack Status
022-978 50 In distribution
022-899 50 In distribution
013-046 25 In distribution
022-270 25 In distribution
022-898 100 In distribution
024-174 10 Withdrawn
011-817 10 Withdrawn
022-659 Hematocrit 20 – 60% Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
True Metrix Trividia Health, Inc. 15
Contour® Ascensia Diabetes Care US Inc. 10
Fora Fora Care Inc. 9
Contour® Next ONE Ascensia Diabetes Care US Inc. 9
True Metrix GO Trividia Health, Inc. 8
Accu-Chek Aviva Plus Roche Diagnostics Operations 7
McKesson Mckesson Medical-Surgical Inc. 7
Accu-Chek Guide Roche Diagnostics Operations 7
Contour® Next Ascensia Diabetes Care US Inc. 6
Accu-Chek Smart View Roche Diagnostics Operations 6
FreeStyle Lite Abbott Diabetes Care Limited 5
Precision Xtra Abbott Diabetes Care Limited 5

Showing 12 of 124. All products under Glucose Dehydrogenase, Glucose

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer