Liaison® 25 OH Vitamin D Total Assay

Catalogue number 310600, listed by Diasorin Inc., United States, under System, Test, Vitamin D. 1 manufacturer in China is registered for this product code.

Registry build 21.09.26
1manufacturer
1catalogue number
6510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Registered in Guangdong.

Chinese manufacturers registered for FDA product code MRG
Manufacturer City Province Registered as Device types
Shenzhen NEW Industries Biomedical Engineering Co., Ltd. Shenzhen Guangdong Manufacturer 4

Record

Regulatory record for Liaison® 25 OH Vitamin D Total Assay
Listed by Diasorin Inc., United States
FDA product code MRG
Device type System, Test, Vitamin D
Device class Class 2
Regulation 21 CFR 862.1825
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Record published 2016-09-24
Record revised 2026-01-14 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Packaging Box of 10

Catalogue Numbers

Catalogue numbers for Liaison® 25 OH Vitamin D Total Assay
Catalogue number Size Status
310600 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
BioPlex 2200 Bio-Rad Laboratories Inc. 6
Access 25(OH) Vitamin D Total Beckman Coulter, Inc. 3
Maglumi 25-OH Vitamin D Shenzhen NEW Industries Biomedical Engineering Co., Ltd. 3
Architect Abbott Medical 3
Atellica™ IM VitD Siemens Healthcare Diagnostics Inc 2
1,25 Dihydroxy Vitamin D RIA Immunodiagnostic Systems Ltd. 2
Maglumi 2000 25-OH Vitamin D Shenzhen NEW Industries Biomedical Engineering Co., Ltd. 2
Alinity Abbott Ireland 2
Architect Abbott Ireland 2
Elecsys Vitamin D total II Roche Diagnostics Gmbh 2
IDS-iSYS 25 VitDS Immunodiagnostic Systems Ltd. 2
Elecsys Vitamin D total III Roche Diagnostics Gmbh 2

Showing 12 of 50. All products under System, Test, Vitamin D

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K141463 2014-12-10
K132492 2013-09-05
K112725 2012-01-20
K071480 2007-10-01
K032844 2004-02-12
K014030 2002-03-26

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2008-02-01 Not classified Nonconforming Material/Component Inaccurate measurements: Kits may sporadically recover kit and external control values out of range high. 2,267 kits 2008-10-31
2007-08-21 Not classified Other 25 Hydroxyvitamin D RIA kits may contain the incorrect lot of tracer. 117 kits 2008-10-17
2006-06-05 Not classified Other Potential for the DiaSorin Kit 1,25-Dihydroxyvitamin D RIA Kit Control 1 (lot 548520) & 2 (lot 548521) to recover out of the defined range, LOW. (If one or both of the kit controls recover outside the defined range, the run is considered 715 2007-06-25
2005-02-14 Not classified Other An internal inspection indicates that Calibrator 2 and Conjugate are switched in their positions in the integral. This will result in Calibrator 1 RLU’s similar to that of background RLU, and Calibrator 2 RLU’s near expected range. A curv 31 kits 2006-07-22
2005-02-14 Not classified Other Results of an internal inspection show Lot 114439E to have calibrator 1 and Calibrator 2 switched in their position in the integral. This results in an inability to calculate a curve, due to the reversal of calibrator values. 131 2006-07-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.