Architect
3 catalogue numbers from 4P52-11, listed by Abbott Medical, United States, under Hemoglobin A1c Test System. 2 manufacturers in China are registered for this product code.
2manufacturers in China registered for this device type
3catalogue numbers in this listing
Who Else Makes It
All of them in Shanghai.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Medconn Medical Technology Co., Ltd. | Shanghai | Shanghai | Manufacturer | 2 |
| Shanghai Medconn Biotechnology Co., Ltd. | Jinshan District | Shanghai | Manufacturer | 2 |
Record
| Listed by | Abbott Medical, United States |
|---|---|
| FDA product code | PDJ |
| Device type | Hemoglobin A1c Test System |
| Device class | Class 2 |
| Regulation | 21 CFR 862.1373 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-09-09 |
| Record revised | 2020-10-13 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Do not freeze.; Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 4P52-11 | In distribution | |
| 4P52-22 | In distribution | |
| 4P52-20 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| D-100 | Bio-Rad Laboratories Inc. | 4 |
| D-10 | Bio-Rad Laboratories Inc. | 3 |
| Afinion HbA1c Dx | Abbott Diagnostics Technologies AS | 2 |
| Tina-quant Hemoglobin A1cDx Gen.3 | Roche Diagnostics Gmbh | 2 |
| Alinity | Abbott Medical | 1 |
| HbA1c Assay | Sekisui Diagnostics, LLC | 1 |
| Dimension Vista System Flex reagent cartridge A1C KIT | Siemens Healthcare Diagnostics Inc | 1 |
| Eluent 80B | Arkray USA, Inc. | 1 |
| BioHermes Automated Glycohemoglobin Analyzer | Wuxi Biohermes BIO & Medical Technology Co., Ltd. | 1 |
| Diluent 80 | Arkray USA, Inc. | 1 |
| Eluent 80A | Arkray USA, Inc. | 1 |
| Hemolysis Washing Solution 80H | Arkray USA, Inc. | 1 |
Showing 12 of 18. All products under Hemoglobin A1c Test System
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Abbott Laboratories | UDI-DI | 2022-06-09 | Class II | Under Investigation by firm | There is a potential for falsely elevated Hemoglobin %A1c and Hemoglobin A1c results to be generated using the ARCHITECT and Alinity c Hemoglobin A1c assay. | 103,316 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.