Bigfoot Unity Diabetes Management System

Bigfoot Unity combines a FreeStyle Libre 2 glucose sensor, reusable caps for rapid-acting and long-acting insulin pens, and a mobile app. The rapid-acting cap displays glucose data and dose…

Registry build 21.09.26

Bigfoot Unity combines a FreeStyle Libre 2 glucose sensor, reusable caps for rapid-acting and long-acting insulin pens, and a mobile app. The rapid-acting cap displays glucose data and dose information based on the prescribed regimen.

The long-acting cap displays the prescribed long-acting dose. Users select and inject insulin manually with compatible disposable pens; the caps provide information rather than operating an automatic infusion mechanism.

Listed Item

Bigfoot Unity Diabetes Management System for Humalog-Lispro-Lyumjev and Levemir-Tresiba-Degludec Only

Communication and Records

The components communicate through NFC and Bluetooth. Both pen caps track dose timing, while the app provides glucose-related alerts, historical information and entry of the clinician-prescribed regimen. The system is intended for single-patient use in people aged 12 or older.

1manufacturer
39catalogue numbers in this listing
2510(k) clearances naming this product code
1recall

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code QLG
Manufacturer City Province Registered as Device types
Flextronics Medical Device Manufacturing (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 6

Record

Regulatory record for Bigfoot Unity Diabetes Management System
Listed by Bigfoot Biomedical, Inc., United States
FDA product code QLG
Device type Integrated Continuous Glucose Monitoring System, Factory Calibrated, Not For Use With Automated Insulin Delivery Systems
Device class Class 2
Regulation 21 CFR 862.1355
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K202145
Record published 2021-06-29
Record revised 2025-07-14 (version 5)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, serial number

Catalogue Numbers

Catalogue numbers for Bigfoot Unity Diabetes Management System
Catalogue number Size Status
ASM-10048 In distribution
ASM-10049 In distribution
FG-300175 In distribution
FG-300187 In distribution
FG-300202 In distribution
FG-300178 In distribution
FG-300200 In distribution
ASM-10053 In distribution
FG-300203 In distribution
ASM-10060 In distribution
FG-300205 In distribution
FG-300206 In distribution
FG-300173 In distribution
FG-300188 In distribution
FG-300177 In distribution
FG-300197 In distribution
FG-300204 In distribution
FG-300172 In distribution
ASM-10051 In distribution
FG-300193 In distribution
FG-300186 In distribution
FG-300184 In distribution
FG-300194 In distribution
ASM-10027 In distribution
ASM-10043 In distribution
SW-300842 In distribution
FG-300171 In distribution
FG-300176 In distribution
FG-300174 In distribution
FG-300196 In distribution
FG-300198 In distribution
FG-300185 In distribution
ASM-10050 In distribution
ASM-10046 In distribution
FG-300191 In distribution
FG-300190 In distribution
FG-300199 In distribution
FG-300179 In distribution
FG-300192 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Bigfoot Unity Bigfoot Biomedical, Inc. 15
FreeStyle Libre 2 Abbott Diabetes Care Limited 4
FreeStyle Libre 3 Abbott Diabetes Care Limited 2
FreeStyle Libre 3 App Abbott Diabetes Care Limited 2
Libre App Abbott Diabetes Care Limited 1
FreeStyle Libre 2 App Abbott Diabetes Care Limited 1

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K222280 2023-03-01
K202145 2021-05-07

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Bigfoot Unity Diabetes Management System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Bigfoot Biomedical, Inc. 510(k) number 2025-05-21 Class II Software design Due to a software/firmware issue diabetes management system may provide a device error and cause the insulin pen to become unresponsive and unable to function. This error may pose a potential health risk for people living with diabetes as 57 pen caps

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer