Citrine Qtrap MS/MS
The Citrine system is a liquid chromatography-tandem mass spectrometry (LC-MS/MS) systems intended to identify inorganic or organic compounds in human specimens by ionizing the compound…
The Citrine system is a liquid chromatography-tandem mass spectrometry (LC-MS/MS) systems intended to identify inorganic or organic compounds in human specimens by ionizing the compound under investigation and separating the resulting ions by means of an electrical field according to their mass.
Who Else Makes It
All of them in Shandong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Labpeak Co., Ltd. | Jinan | Shandong | Manufacturer | 43 |
| Scitek Global Co., Ltd. | Jinan | Shandong | Manufacturer | 43 |
Record
| Listed by | AB Sciex (Manufacturing) |
|---|---|
| FDA product code | DOP |
| Device type | Mass Spectrometer, Clinical Use |
| Device class | Class 1 |
| Regulation | 21 CFR 862.2860 |
| Premarket notification | Exempt |
| Record published | 2022-09-28 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 5050807 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Xevo | Waters Corporation | 6 |
| LCMS-8050 CL | Shimadzu Corp. | 3 |
| LCMS-8060 CL | Shimadzu Corp. | 2 |
| LCMS-8040 CL | Shimadzu Corp. | 2 |
| SpectroChip CPM Kit (2×96) | Agena Bioscience Incorporated | 1 |
| Triple Quad™ 4500MD | AB Sciex (Manufacturing) | 1 |
| TopazTM System | AB Sciex (Manufacturing) | 1 |
| cobas pro i 601 BL | Roche Diagnostics Gmbh | 1 |
| K6460 Triple Quadrupole MS → AJS | Agilent Technologies, Inc | 1 |
| SpectroChip CPM Kit (10×96) | Agena Bioscience Incorporated | 1 |
| cobas i 601 SBL | Roche Diagnostics Gmbh | 1 |
| SpectroChip Standalone Chip Only) | Agena Bioscience Incorporated | 1 |
Showing 12 of 27. All products under Mass Spectrometer, Clinical Use
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Ab Sciex, LLC | UDI-DI | 2023-08-30 | Class II | Component design/selection | In rare occasions, the combination of a leak of a highly flammable solvent at the ion source probe, and an electrical discharge may result in a flame on top of the probe and possible ejection of the electrode assembly from the probe. There | 10 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.