DxC AU

DxC 700 AU Chemistry Analyzer, Direct Track Sampling

Registry build 21.09.26
16manufacturers in China registered for this device type
6catalogue numbers in this listing
1510(k) clearance
40recalls on this code

Who Else Makes It

Concentrated in Guangdong (5), Jiangsu (3), Zhejiang (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code JJE
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24
Beckman Coulter Laboratory Systems (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 4
Zhejiang Orient Gene Biotech Huzhou Zhejiang Contract manufacturer 86
Biobase Biodustry(Shandong)Co., Ltd. Jinan Shandong Manufacturer 70
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Shenzhen Yhlo Biotech Co., Ltd. Shenzhen Guangdong Manufacturer 19
Getein Biotech, Inc. Nanjing Jiangsu Manufacturer 19
Beijing Hotgen Biotech Co., Ltd. Beijing Beijing Manufacturer 13
Yantai Addcare Bio-Tech Co., Ltd. Yantai Shandong Contract manufacturer 8
Shenzhen NEW Industries Biomedical Engineering Co., Ltd. Shenzhen Guangdong Manufacturer 4
Shanghai Kehua Laboratory System Co., Ltd. Shanghai Shanghai Manufacturer 4

Showing 12 of 16. All 16 manufacturers in China registered for Analyzer, Chemistry (Photometric, Discrete), For Clinical Use

Record

Regulatory record for DxC AU
Listed by Beckman Coulter, Inc., United States
FDA product code JJE
Device type Analyzer, Chemistry (Photometric, Discrete), For Clinical Use
Device class Class 1
Regulation 21 CFR 862.2160
Establishment Contract manufacturer, Specification developer, Manufacturer, Exporter
Record published 2020-08-24
Record revised 2024-10-28 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for DxC AU
Catalogue number Size Status
B86444 In distribution
C63520 In distribution
B86443 In distribution
C63519 In distribution
B86446 In distribution
B86445 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Alinity Abbott Medical 283
Architect Abbott Laboratories 115
Alinity Abbott Laboratories 18
Biobase Biobase Biodustry(Shandong)Co., Ltd. 15
Vitros Ortho-Clinical Diagnostics, Inc. 14
Architect Abbott Ireland Diagnostics 8
AU Beckman Coulter, Inc. 7
Alinity Abbott Ireland Diagnostics 6
Chemiluminescence Immunoassay Analyzer Shenzhen Yhlo Biotech Co., Ltd. 6
Automated Chemiluminescent Enzyme Immunoassay Analyzer AIA-CL300 Tosoh Corp. 5
Pictus 500 Clinical chemistry analyzer Diatron Medicinai Instrumentumok Laboratoriumi Diagnosztikai Fejleszto-Gyarto Zartkoruen Mukodo Reszvenytarsasag 4
Vidas 3 bioMerieux, Inc. 3

Showing 12 of 336. All products under Analyzer, Chemistry (Photometric, Discrete), For Clinical Use

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K023764 2003-01-28

Recalls Naming This Product

6 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of DxC AU
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Beckman Coulter, Inc. UDI-DI 2026-07-15 Class II Software design (manufacturing process) a software defect in which the Parameter Package (PP)
import logic overwrites all predefined calculated test rules, including those previously
modified by the user, upon import of a new Parameter Package version. As a result, usercustomized
Beckman Coulter, Inc. UDI-DI 2025-03-20 Class II Software design Beckman Coulter is recalling their DxC 500 AU Clinical Chemistry Analyzer because a software error causes the analyzer to not run a requested calibration order in the following scenario: when a reagent blank or calibration is ordered durin
Beckman Coulter, Inc. UDI-DI 2025-03-17 Class II Under Investigation by firm The reason for the recall is incorrect sample barcode identification and processing errors that result in the reporting of erroneous and delayed results. 136 systems (U.S. 68 and O.U.S. 68)
Beckman Coulter, Inc. UDI-DI 2025-02-26 Class II Software design Beckman Coulter has determined that device software versions V1.3, V1.4, V1.4.1, V1.4.2, V1.4.3. have a defect due of which, when all constituent tests of a calculated result are rerun, either manually ordered by the operator at the analyze 143 systems (U.S. 74 and O.U.S. 69)
Beckman Coulter Mishima K.K. UDI-DI 2024-07-10 Class II Software design Due to a software issues, after the instrument processes 250 racks cumulatively, any subsequent racks with samples requiring rerun/reflex will be held in the Sample Handler’s Buffer area and and error code “9000” will be reported. This iss 24 analyzers
Beckman Coulter Mishima K.K. UDI-DI 2024-06-05 Class II Software design There are two software bug issues with the analyzer. Issue 1: When a dedicated rack is reserved for calibration, after a calibration test has been placed and completed, the same rack may be used to place both a patient order and a calibrati 24 analyzers

Recalls

36 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-07-15 Class II Software design (manufacturing process) a software defect in which the Parameter Package (PP)
import logic overwrites all predefined calculated test rules, including those previously
modified by the user, upon import of a new Parameter Package version. As a result, usercustomized
2025-11-26 Class II Device Design Beckman Coulter has determined that, due to a potential communication issue, the analyzers listed above may not successfully restart following a standard shutdown, even after multiple attempts. If this issue occurs, the instrument will be u 1272 units
2025-11-26 Class II Device Design Beckman Coulter has determined that, due to a potential communication issue, the analyzers listed above may not successfully restart following a standard shutdown, even after multiple attempts. If this issue occurs, the instrument will be u 6457 units
2025-11-07 Class II Process design It has been determined that certain lots of Access 2 Reaction Vessels may contain manufacturing deformities. The bottom (round end) of the Reaction Vessel may have a small protrusion or hair like deformity. This could cause causing instrume 38,225 untis
2025-10-01 Class II Process control An internal investigation has determined that due to defective sub-components within the gantry assembly, a z-axis CAD movement motion error may occur and cause an analyzer to enter a Not Ready or Paused state, leading to a delay in obt 657 units
2025-10-01 Class II Process control An internal investigation has determined that due to defective sub-components within the gantry assembly, a z-axis CAD movement motion error may occur and cause an analyzer to enter a Not Ready or Paused state, leading to a delay in obt 80 units
2025-06-25 Class II Device Design Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (in 177 systems
2025-06-25 Class II Device Design Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (in 451 systems
2025-06-25 Class II Device Design Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (in 1 system
2025-06-25 Class II Device Design Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (in 2203 systems
2025-06-25 Class II Device Design Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (in 271 systems
2025-06-25 Class II Device Design Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (in 1 system
2025-05-07 Class II Software design Analyzer has calibration issues where curves switched from passed to failed due to system errors during aspiration. This anomaly causes erroneous results and delays if unnoticed. RLU values may be misinterpreted as valid measurements by LIS 67 US; 178 OUS
2025-03-27 Class II Software design When DxI 9000 Access Immunoassay Analyzer is connected to a host system (laboratory information system (LIS) or middleware) and has accumulated canceled QC test results that were not sent by LIS, the analyzer may lose communication with the 370 units
2025-02-06 Class II Device Design Beckman Coulter identified that an issue for DxI 9000 tip stocker interface (TSI) and reagent storage interface (RSI) boards with the firmware version 1.1.0.0 can cause sub-system communication failures. This failure could result in a delay 80 units
2025-02-05 Class II Process design the DxI 9000 encoder wheel was misaligned on the motor shaft, leading to increased slippage errors and causing the instrument to stop, posing a high safety risk due to potential delays in patient results. 206 units
2025-02-05 Class II Nonconforming Material/Component Beckman Coulter identified that an issue for Access 2 Sample Motors (B48016) due to improper alignment, causing the motors to rub against the sample wheelbase plate and index sensor. The issue was traced to a worn tool used in production (a 873 units
2024-11-13 Class II Nonconforming Material/Component The DxI 9000 Access Immunoassay
Analyzer wash wheel mixer may not spin freely within the idler pulley housing. When the problem occurs, the analyzer may generate a system event for a Wash Wheel Dispense Arm Spin Mixer Error that is displaye
245 units
2024-07-12 Class II Device Design Ground screws on Dxl 9000 PCB boards may cause electric shorts, leading to smoke and potentially delaying patient results. Smoke also poses a hazard to equipment and users. 30 OUS
2024-07-10 Class II Nonconforming Material/Component Beckman Coulter is recalling the DxI 9000 Access Immunoassay Analyzer due to undersized Pneumatics Tubing in the reagent storage module causing air leaks, compressor failures or sample processing errors. Four complaints were filed for this 170 units
2024-06-14 Class II Under Investigation by firm Beckman Coulter, Inc. has identified a rise in reagent carousel motion errors in Access 2 Immunoassay System Analyzers that appear to be caused by misaligned index wheels housed within the reagent carousel module. Customers affected by this 59 units
2024-06-04 Class II Nonconforming Material/Component The analyzers were built with nonconforming USB cables made with brass contacts instead of specified gold contacts. Brass contacts may corrode over time, leading to loss of internal instrument communication and delayed patient results. 143 devices
2024-05-22 Class II Software design When a DxI 9000 Access Immunoassay Analyzer is connected to a Laboratory Automation System (LAS) and is running with the system software versions 1.17.0 and below, the analyzer does not send a message to the LAS when the sample wheel is ful 183 analyzers
2024-05-22 Class II Software design The reason for this recall is Beckman Coulter has determined that when a DxI 9000 Access Immunoassay Analyzer is connected to a Laboratory Automation System (LAS); is running with the software versions 1.17 and below; and a sample tube is s 183 devices
2024-04-18 Class II Software design When the DxI 9000 Access Immunoassay Analyzer with system software version 1.16.2 and prior is configured to automatically request a calibration order, the instrument can process the order with expired calibrator material. If the calibratio 164 units
2024-04-18 Class II Software design Beckman Coulter is recalling their DxI 9000 Access Immunoassay Analyzers, an in vitro diagnostic device used for the quantitative, semi-quantitative, or qualitative determination of various analyte concentrations found in human body fluids, 116 units
2024-03-05 Class II Process control Beckman Coulter manufacturing discovered cracks around a threaded insert on the bottom of the Internal Wash Buffer Tank that is used within the Wash Buffer Supply Drawer on the DxI 9000.This can result in leaking, leading to delays in repor 17 units
2024-02-29 Class II Under Investigation by firm The reason for the recall is the pneumatic tubing used in the analytical pick-and-place (PnP) assembly cable may fully or partially disconnect from the flex cable assembly fittings during normal operation. The DxI 9000 Access Immunoassay An 9 instruments
2024-01-03 Class II Software design A software error caused an increase in tray gripper motion errors that causes intermittent hard stops and a delay in patient results. 61 units
2023-11-21 Class II Software design There are potential performance issues found in the DxI 9000 Access Immunoassay Analyzer, including: 1) Access Ultrasensitive Insulin users who configure SI units (pmol/L) applies an incorrect conversion
factor; 2) System provides numerical
128 analyzers
2023-09-12 Class II Software design The firm has investigated and confirmed that when DxI 9000 is connected to Laboratory Information System (LIS, host), the sample barcode presented may be ignored and replaced with a sample ID that was previously in the same rack and positio 36 units
2023-06-20 Class II Under Investigation by firm Beckman Coulter, Inc. is recalling Ringed DxI Reaction Vessels (RVs) as part of Unicel DxI Immunoassay System (600, 800 series). The reason for the recall is that the firm has identified 3 lots of RVs that failed an internally used service 213 cases of 10,000 RVs (2,130,000 RVs)
2023-01-26 Class II Component change control An increased incidence of damage to the nut band from a new vendor (Boamax) has led to an increased volume of complaints from consignees regarding wash arm motion failures, system check failures, and/or assay performance leading to a remote 4,137 devices (990 U.S. and 3,147 OUS)
2021-07-21 Class II Under Investigation by firm There is a potential that sample carriers (w or w/o samples) within automated sampling system may transport samples to the outer lane which does not contain a physical barrier to restrain samples. Samples are dropped when they reach the 123 systems 2024-10-10
2019-05-17 Class II Software design Potential exposure to biohazard.
Software design problem causes excess speed and vibrations in the unload arm movement which causes caused sample splashing.
291 units 2022-03-11
2018-12-05 Class II Under Investigation by firm When racks are front-loaded onto the sample presentation unit while samples from the automation line are being processed, a scheduling error within the software can cause mishandling of samples during the creation of an aliquot and lead to 2842

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.